Altinex Network Card CNK221 User Manual

DESIGNER SOLUTIONS  
MANUAL PART NUMBER: 400-0133-003  
CNK221/CNK231  
CABLE-NOOK JR.™  
INTERCONNECT BOX  
USER’S GUIDE  
 
DESIGNER SOLUTIONS  
PRECAUTIONS / SAFETY WARNINGS  
1
1.3 CLEANING  
· Surfaces should be cleaned with a dry cloth.  
Never use strong detergents or solvents, such  
as alcohol or thinner. Do not use a wet cloth or  
water to clean the unit.  
Please read this manual carefully before using your  
Tabletop Cable-Nook Jr.Interconnect Box. Keep  
this manual handy for future reference. These  
safety instructions are to ensure the long life of  
your Cable-Nook Jr.and to prevent fire and shock  
hazard. Please read them carefully and heed all  
warnings.  
1.4 FCC / CE NOTICE  
· This device complies with part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
1.1 GENERAL  
· Unauthorized personnel shall not open the unit  
since there are high-voltage components inside.  
· Qualified ALTINEX service personnel, or their  
authorized representatives must perform all  
service.  
· This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference when the  
1.2 INSTALLATION  
· For best results, place the Tabletop Cable-Nook  
Jr.Interconnect Box in a dry area away from  
dust and moisture.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and, if  
not installed and used in accordance with the  
instruction manual, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at his own expense.  
· To prevent fire or shock, do not expose this unit  
to rain or moisture. Do not place the Tabletop  
Cable-Nook Jr.Interconnect Box in direct  
sunlight, near heaters or heat radiating  
appliances, or near any liquid. Exposure to  
direct sunlight, smoke, or steam can harm  
internal components.  
· Handle  
the  
Tabletop  
Cable-Nook  
Jr.™  
Interconnect Box carefully. Never lay the Cable-  
Nook Jr.on the thin bezel lip. Dropping, jarring  
or striking the bezel may damage it.  
· Any changes or modifications to the unit not  
expressly approved by ALTINEX, Inc. could void  
the user’s authority to operate the equipment.  
· Never place fingers inside the openings in the  
sides of the unit or along the bezel edges. The  
sharp edges may cause serious injury.  
ABOUT YOUR CABLE-NOOK Jr.™  
2
· Do not place heavy objects on top of the  
Tabletop Cable-Nook Jr.Interconnect Box. Do  
not use excessive force to push down on the top  
of the unit.  
The Tabletop Cable-Nook Jr.Interconnect Box is  
designed for installation into a conference room or  
boardroom table. The Cable-Nook Jr.provides a  
means of connecting audio, video, and other  
multimedia sources into a presentation system. It is  
ideal for use with ALTINEX computer video  
interfaces or distribution amplifiers.  
· Tabletop cutout dimensions and templates can  
be obtained from the Altinex website at  
The Tabletop Cable-Nook Jr.Interconnect Box  
provides a simple yet effective way of storing and  
hiding cables, eliminating the obstruction. The  
2
 
DESIGNER SOLUTIONS  
cables can remain connected to a presentation  
system, enabling the user to connect them to  
different media sources needed for a presentation.  
After the presentation, the cables may be returned  
to the Cable-Nook Jr.for safe storage.  
The Tabletop Cable-Nook Jr.Interconnect Box is  
designed for use with tabletops up to three inches  
thick. Optional insert plates are available to secure  
the cable ends or to add connections for a variety  
of multimedia and power cables. The insert plates  
can be adjusted to fit a variety of cable sizes. The  
height of the insert plates can also be adjusted by  
changing the height of the interior bracket mounts  
in the Cable-Nook Jr..  
All specifications are subject to change without  
notice. See www.altinex.com for up-to-date  
information.  
FEATURES/DESCRIPTION  
CNK221/CNK231  
MECHANICAL  
Bezel Width, inches [mm]  
Bezel Depth, inches [mm]  
Bezel Dia. (CNK231), inches [mm]  
Height (cover open), inches [mm]  
Height (cover closed), inches [mm]  
Standard Finish  
4.60” [117mm]  
4.90” [124.5mm]  
5.75” [146mm]  
7.42” [188mm]  
4.79” [122mm]  
Matte Black  
10°C-35°C  
T° Operating  
T° Maximum  
50°C  
90% non-  
condensing  
Humidity  
Table 1. Cable-Nook Jr.Mechanical  
TECHNICAL SPECIFICATIONS  
3
3
 
DESIGNER SOLUTIONS  
DESCRIPTION OF CABLE-NOOK Jr.™  
4
Diagram 1: Dimensions  
(All dimensions are ± .03 [± 0.8mm])  
BRACKET MOUNTS  
FOR INSERT PLATES  
4.90"  
[124.5mm]  
INTERIOR VIEW  
(Cover Removed)  
4.60"  
[117mm]  
5.75" DIA.  
[146mm DIA.]  
CNK221  
Dimensions  
CNK231  
Dimensions  
SIDE VIEW  
2.68" [68mm]  
Opened  
4.79"  
4.76"  
[122mm]  
(To Top of Lip)  
[121mm]  
(Below Lip)  
3.48"  
[88mm]  
3.75"  
[95mm]  
3.75"  
[95mm]  
4.08"  
[104mm]  
4.10"  
[104mm]  
5.25" DIA.  
[133mm DIA.]  
4.40"  
[112mm]  
For tabletop cutout dimensions, see www.altinex.com.  
4
 
DESIGNER SOLUTIONS  
APPLICATION DIAGRAM  
5
Diagram 2: Application Example  
Laptop  
Computer  
Inputs  
Computer Video + Audio  
Interface  
Network  
Telephone  
Video + Audio  
AC Power  
CNK221  
CNK231  
To Projector,  
Racks, or  
Con
t
rol
R
o
om  
5
 
DESIGNER SOLUTIONS  
INSTALLING YOUR CABLE-NOOK Jr.™  
6
OPERATION  
7
Step 1. Cut an opening in the table’s surface.  
Refer to www.altinex.com for table cutout  
dimensions and templates. The tabletop  
Lift the Cable-Nook Jr.’s cover to install or route  
cables. If the cables need to be connected  
while the lid is closed, route the cables  
through the open space in the front of the  
lid. Unconnected cables may be stored  
inside the Cable-Nook Jr.. until they are  
needed.  
thickness must be 3 inches [76mm] or less.  
Always confirm dimensions before  
cutting the table to ensure that the  
specifications have not changed.  
Step 2. Adjust the bracket mounts inside the unit to  
suit your needs. CAUTION! Do not handle  
the unit by the bezel’s thin lip or lay it  
on it’s side on the lip. The thin bezel lip  
is very sharp and can be easily dented  
or bent. Handle the unit by the housing  
portion only. Remove the two screws  
securing each bracket to the interior  
housing if necessary to place them at the  
level that you require using the holes on  
the side of the housing. Replace the  
screws on each bracket mount after  
making sure that they are at exactly the  
same level.  
Step 3. Insert the Cable-Nook Jr.unit into the  
tabletop cutout. Place a mounting bracket  
with the thumbscrew installed into the  
support mounts on each side of the  
housing as shown in Figure 1. With the  
mounting brackets installed, turn the  
thumbscrews until the ends of the screws  
begin to push against the bottom of the  
table. Tighten the screws until the unit is  
secure. Do not over-tighten.  
TABLETOP  
SUPPORT BRACKET  
THUMBSCREW  
Figure 1: Securing the Cable-Nook Jr.to the  
tabletop.  
SUPPORT MOUNTS  
SUPPORT MOUNTS  
HOUSING  
6
 
DESIGNER SOLUTIONS  
ACCESSORIES  
Model No.  
8
ALTINEX POLICY  
10  
Description  
10.1 LIMITED WARRANTY / RETURN POLICY  
CN5101US Insert plate w/ 1 U.S. AC connector  
CN5102US Insert plate w/ 2 U.S. AC connectors  
Please see the Altinex website at www.altinex.com  
for details on warranty and return policy.  
Blank insert plates, set of 5  
Insert plate w/ 2 empty snap-in ports  
Insert plate w/ 4 empty snap-in ports  
CN5110RB  
CNK-IP-105  
CNK-IP-106  
If your product is out of warranty and needs service,  
contact the ALTINEX Sales Department for an RMA  
(Return Material Authorization). Products returned  
without an RMA number may experience a delay in  
service. The service charges will be quoted to you  
before the actual repairs are done.  
Insert plate w/ a 15-pin HD female to  
CNK-IP-107 male 6ft [1.8m] cable and 2 empty  
snap-in ports  
Insert plate w/ 1 empty D-Sub  
CNK-IP-108 connector port for a DB9 or HD15  
connector  
10.2 CONTACT INFORMATION  
ALTINEX, INC.  
Insert plate w/ a 15-pin HD female to  
male 6ft [1.8m] cable  
CNK-IP-109  
592 Apollo Street  
Please check www.altinex.com for additional  
accessories and cables.  
Brea, CA 92821 USA  
TEL: 714-990-2300  
TROUBLESHOOTING GUIDE  
9
TOLL FREE: 1-800-ALTINEX  
The supplied Cable-Nook Jr.unit was carefully  
tested and no problems were detected. However,  
we would like to offer these recommendations:  
FAX: 714-990-3303  
· Please make sure that the highest quality video,  
audio, and any other cables or connectors are  
used.  
· Make sure that cables have not been damaged  
or pinched. If there is damage to the unit then do  
not use the Cable-Nook Jr.unit. Immediately  
contact the ALTINEX Customer Service  
Department to have the unit repaired.  
· There are no adjustments necessary to operate  
the Cable-Nook Jr., the unit will operate  
successfully as long as the cables are attached  
properly and other technical specifications are  
followed.  
7
 

3M Power Hammer 000 RPM 100 mm 4 in User Manual
3M VCR M 920 User Manual
Aastra Telecom Corded Headset BE 100HT User Manual
Abocom Switch PLS322 User Manual
Advantek Networks Network Router AWN AP 54MR User Manual
American Audio Music Mixer M1624FX User Manual
American Dryer Corp Clothes Dryer AD 15 thru AD 75 User Manual
AMX Stereo Amplifier AVB DA RGBHV ST 0102 User Manual
Avenview Switch KVM C5 Series User Manual
Baby Trend Stroller 7581 User Manual