Axis Communications Security Camera T90B15 W LED User Manual

AXIS T90B Series  
AXIS T90B15 W-LED  
AXIS T90B25 W-LED  
AXIS T90B35 W-LED  
AXIS T90B20 IR-LED  
AXIS T90B30 IR-LED  
AXIS T90B40 IR-LED  
Installation Guide  
 
Legal Considerations  
A copy of the original declaration of conformity  
may be obtained from Axis Communications AB. See  
Contact Information on page 3 .  
Video and audio surveillance can be regulated by  
laws that vary from country to country. Check the  
laws in your local region before using this product  
for surveillance purposes.  
Electromagnetic Compatibility (EMC)  
This equipment has been designed and tested to fulfill  
applicable standards for:  
Liability  
Every care has been taken in the preparation of this  
document. Please inform your local Axis office of  
any inaccuracies or omissions. Axis Communications  
AB cannot be held responsible for any technical or  
typographical errors and reserves the right to make  
changes to the product and manuals without prior  
notice. Axis Communications AB makes no warranty  
of any kind with regard to the material contained  
within this document, including, but not limited to,  
the implied warranties of merchantability and fitness  
for a particular purpose. Axis Communications AB  
shall not be liable nor responsible for incidental  
or consequential damages in connection with the  
furnishing, performance or use of this material. This  
product is only to be used for its intended purpose.  
Radio frequency emission when installed  
according to the instructions and used in its  
intended environment.  
Immunity to electrical and electromagnetic  
phenomena when installed according to  
the instructions and used in its intended  
environment.  
USA  
This equipment has been tested using a shielded  
network cable (STP) and found to comply with the  
limits for a Class B digital device, pursuant to part 15  
of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference in  
a residential installation. This equipment generates,  
uses and can radiate radio frequency energy and,  
if not installed and used in accordance with the  
instructions, may cause harmful interference to radio  
communications. However, there is no guarantee that  
interference will not occur in a particular installation.  
If this equipment does cause harmful interference  
to radio or television reception, which can be  
determined by turning the equipment off and on, the  
user is encouraged to try to correct the interference  
by one or more of the following measures:  
Intellectual Property Rights  
Axis AB has intellectual property rights relating to  
technology embodied in the product described in this  
document. In particular, and without limitation, these  
intellectual property rights may include one or more  
of the patents listed at www.axis.com/patent.htm and  
one or more additional patents or pending patent  
applications in the US and other countries.  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
Equipment Modifications  
This equipment must be installed and used in  
strict accordance with the instructions given in  
the user documentation. This equipment contains  
no user-serviceable components. Unauthorized  
equipment changes or modifications will invalidate  
all applicable regulatory certifications and approvals.  
Connect the equipment into an outlet on a  
circuit different from that to which the receiver  
is connected.  
Consult the dealer or an experienced radio/TV  
technician for help.  
The product shall be connected using a shielded  
network cable (STP) that is properly grounded.  
Trademark Acknowledgments  
AXIS COMMUNICATIONS, AXIS, ETRAX, ARTPEC  
and VAPIX are registered trademarks or trademark  
applications of Axis AB in various jurisdictions. All  
other company names and products are trademarks or  
registered trademarks of their respective companies.  
Canada  
This Class B digital apparatus complies with Canadian  
ICES-003. The product shall be connected using  
a shielded network cable (STP) that is properly  
grounded.  
Regulatory Information  
Cet appareil numérique de la classe B est confome à  
la norme NMB-003 du Canada. Le produit doit être  
connecté à l'aide d'un câble réseau blindé (STP) qui  
est correctement mis à la terre.  
Europe  
This product complies with the applicable  
CE marking directives and harmonized standards:  
Europe  
This digital equipment fulfills the requirements for RF  
emission according to the Class B limit of EN 55022.  
The product shall be connected using a shielded  
network cable (STP) that is properly grounded.  
Electromagnetic Compatibility (EMC)  
Directive 2004/108/EC. See Electromagnetic  
Compatibility (EMC) on page 2 .  
Low Voltage (LVD) Directive 2006/95/EC. See  
Safety on page 3 .  
This product fulfills the requirements for immunity  
according to EN 61000-6-1 residential, commercial  
and light-industrial environments.  
Restrictions of Hazardous Substances (RoHS)  
Directive 2011/65/EU. See Disposal and  
Recycling on page 3 .  
This product fulfills the requirements for immunity  
according to EN 61000-6-2 industrial environments.  
 
 
Australia/New Zealand  
223 69 Lund  
Sweden  
This digital equipment fulfills the requirements  
for RF emission according to the Class B limit of  
AS/NZS CISPR 22. The product shall be connected  
using a shielded network cable (STP) that is properly  
grounded.  
Tel: +46 46 272 18 00  
Fax: +46 46 13 61 30  
Korea  
Support  
기기는 가정용(B급) 전자파적합기기로서  
Should you require any technical assistance, please  
contact your Axis reseller. If your questions cannot  
be answered immediately, your reseller will forward  
your queries through the appropriate channels to  
ensure a rapid response. If you are connected to the  
Internet, you can:  
주로 가정에서 사용하는 것을 목적으로 하며,  
모든 지역에서 사용할  
있습니다. 적절히  
접지된 STP (shielded twisted pair) 케이블을  
사용하여 제품을 연결 하십시오.  
Safety  
This product complies with EN 60598–1 Luminaire -  
General requirements and tests.  
download user documentation and software  
updates  
find answers to resolved problems in the FAQ  
database. Search by product, category, or  
phrase  
Photobiological Safety  
This product fulfills the requirements for  
photobiological safety according to IEC/EN 62471  
(risk group 2).  
report problems to Axis support staff by logging  
in to your private support area  
chat with Axis support staff (selected countries  
only)  
Disposal and Recycling  
When this product has reached the end of its  
useful life, dispose of it according to local laws  
and regulations. For information about your  
nearest designated collection point, contact your  
local authority responsible for waste disposal. In  
accordance with local legislation, penalties may be  
applicable for incorrect disposal of this waste.  
visit Axis Support at www.axis.com/techsup/  
Learn More!  
Visit Axis learning center www.axis.com/academy/ for  
useful trainings, webinars, tutorials and guides.  
Europe  
This symbol means that the product shall  
not be disposed of together with household or  
commercial waste. Directive 2012/19/EU on waste  
electrical and electronic equipment (WEEE) is  
applicable in the European Union member states.  
To prevent potential harm to human health and the  
environment, the product must be disposed of in an  
approved and environmentally safe recycling process.  
For information about your nearest designated  
collection point, contact your local authority  
responsible for waste disposal. Businesses should  
contact the product supplier for information about  
how to dispose of this product correctly.  
This product complies with the requirements of  
Directive 2011/65/EU on the restriction of the use  
of certain hazardous substances in electrical and  
electronic equipment (RoHS).  
China  
This product complies with the requirements  
of the legislative act Administration on the Control of  
Pollution Caused by Electronic Information Products  
(ACPEIP).  
Contact Information  
Axis Communications AB  
Emdalavägen 14  
 
     
 
AXIS T90B Series  
Safety Instructions  
WARNING  
The Axis product shall be installed by a trained professional.  
NOTICE  
The Axis product shall be used in compliance with local laws  
and regulations.  
Store the Axis product in a dry and ventilated environment.  
Avoid exposing the Axis product to shocks or heavy pressure.  
Do not install the product on unstable brackets, surfaces or  
walls.  
Use only applicable tools when installing the Axis product.  
Excessive force could cause damage to the product.  
Do not use chemicals, caustic agents, or aerosol cleaners. Use a  
clean cloth dampened with pure water for cleaning.  
Use only accessories that comply with technical specification of  
the product. These can be provided by Axis or a third party.  
Use only spare parts provided by or recommended by Axis.  
Do not attempt to repair the product by yourself. Contact Axis  
support or your Axis reseller for service matters.  
Transportation  
NOTICE  
When transporting the Axis product, use the original packaging  
or equivalent to prevent damage to the product.  
 
6
AXIS T90B Series  
Installation Guide  
This Installation Guide provides instructions for installing AXIS T90B Series.  
Installation Steps  
1. Make sure the package contents, tools and other materials  
necessary for the installation are in order. See page 7 .  
2. Study the hardware overview. See page 8 .  
3. Study the specifications. See page 14.  
4. Install the hardware. See page 15.  
Package Contents  
AXIS T90B Illuminator including power cable  
1 pre-mounted diverging lens  
2 separate diverging lenses  
Optional Accessories  
Mounting brackets  
Remote control  
Diverging lens with additional angle  
Power supply  
For information about available accessories, see www.axis.com  
 
7
 
AXIS T90B Series  
Hardware Overview  
Illuminator  
1
2
3
Photocell  
Cable  
Breather gland  
 
8
 
AXIS T90B Series  
1
2
3
4
5
6
Power cable (red)  
Power cable (black)  
Photocell cable (white)  
Photocell cable (yellow)  
Telemetry cable (purple)  
Telemetry cable (orange)  
 
9
AXIS T90B Series  
1
2
3
4
5
Red LED indicator  
Amber LED indicator  
Green LED indicator  
Remote control receiver  
Mounting bracket (pre-mounted)  
 
10  
AXIS T90B Series  
AXIS T90B40 IR-LED  
1
2
3
Cables  
Mounting bracket (pre-mounted)  
Bolt  
Optional Accessories  
Remote Control  
For information how to use the remote control, see Access the Product.  
 
11  
AXIS T90B Series  
1
2
3
4
5
6
7
8
9
POWER ADJUST buttons  
PHOTOCELL ADJUST buttons  
TIMER buttons  
Photocell disable button  
DIM button  
RESET button  
STATUS button  
Disable remote control setup button  
TELEMETRY button  
Mounting Brackets  
To install the product using a compatible bracket from AXIS T90B  
Mounting Accessories, see the Installation Guide delivered separately with  
the mounting bracket.  
 
12  
AXIS T90B Series  
LED Indicators  
There are three colored LED indicators on the base of the illuminator which  
provide operating and status information. The color status depends on  
the current operating mode:  
Programming Mode  
Normal Operating Mode  
Programming Mode  
LED Indicator  
Solid Green  
Indicated Behavior  
Power on  
Flashing Green  
Solid Amber  
Remote control IR receiver error  
Illuminator receiving valid  
command from remote control  
Flashing Amber  
Solid Red  
Illuminator in Programming Mode  
Internal LED error  
Flashing Red  
Input voltage supply error*  
Normal Operating Mode  
LED Indicator  
Solid Green  
Indicated Behavior  
Power on  
Flashing Green  
Remote control IR receiver error  
 
13  
 
AXIS T90B Series  
Normal Operating Mode (Continued)  
Solid Amber  
Solid Red  
Input voltage level error*  
Internal LED error  
*Once the voltage error has been corrected, disable the remote control  
setup or restart the illuminator to turn the status LED off.  
Connectors and Buttons  
For specifications and operating conditions, see page 14.  
Power Connector  
AC/DC power connector  
Specifications  
Operating Conditions  
Product  
Temperature  
Humidity  
AXIS T90B Series  
-50 °C to 50 °C  
(-58 °F to 122 °F)  
10–100% RH (con-  
densing)  
Power Consumption  
Product  
Value  
AXIS T90B15 W-LED  
AXIS T90B20 IR-LED  
12–24 V AC/DC, max 12 W  
12–24 V AC/DC, max 24 W  
 
14  
 
AXIS T90B Series  
AXIS T90B25 W-LED  
AXIS T90B30 IR-LED  
AXIS T90B35 W-LED  
AXIS T90B40 IR-LED  
12–24 V AC/DC, max 24 W  
12–24 V AC/DC, max 48 W  
12–24 V AC/DC, max 48 W  
12–24 V AC/DC, max 96 W  
For more information about power consumption, see Technical  
Specifications on page 29  
Install the Hardware  
To install the product using a compatible bracket from AXIS T90B  
Mounting Accessories, see the Installation Guide delivered separately with  
the mounting bracket.  
 
15  
 
AXIS T90B Series  
CAUTION  
IR emitted from this product. Avoid prolonged eye exposure or  
use appropriate shielding or eye protection at distances of less  
than 1.5 m.  
Follow these installation procedures:  
1. If required, remove the screws and move the standard bracket  
to the top of the illuminator.  
2. If required, loosen the screws and turn the bracket 90°.  
 
16  
AXIS T90B Series  
3. If required, loosen the screws and change to a diverging  
lens with the desired angle of illumination. The angle of  
illumination should be adjusted according to the camera field  
of view to light the whole scene adequately. See Technical  
Specifications.  
 
17  
AXIS T90B Series  
1
2
Screws  
Diverging lens  
Note  
Adjust the vertical position of the illuminator to ensure that the  
field of view of the camera is illuminated.  
 
18  
AXIS T90B Series  
4. Position the illuminator adjacent to the camera and point the  
illuminator towards the scene.  
CAUTION  
Red cable = +ve, Black cable = -ve (polarity sensitive)  
5. Mount the power supply.  
6. Connect the illuminator to the power supply.  
 
19  
AXIS T90B Series  
1
2
3
Illuminator  
Power cable  
Power supply  
7. Set photocell following output (White & Yellow) Volt free  
output — normally open (day) to normally closed (night).  
Connect direct to camera if required to control switchover  
of day/night cameras.  
Access the Product  
Programming Mode  
The illuminator has the following default settings:  
Power set to maximum 100%  
Photocell set to medium sensitivity level: 10 lux On, 30 lux Off.  
Timer disabled  
 
20  
 
AXIS T90B Series  
Telemetry TEL enabled  
Telemetry input wires soldered together for automatic  
photocell operation  
Telemetry DIM disabled  
LED status indicators enabled  
Programming Mode  
Note  
Changing the settings requires a remote control (optional  
accessory). The illuminator must be in Programming Mode.  
The illuminator automatically switches from Programming  
Mode to Normal Operating Mode after 4 weeks. To switch to  
Programming Mode, restart the illuminator.  
1. Adjust the power, see Power Adjust on page 22.  
2. Adjust the photocell sensitivity, see Photocell Sensitivity on  
page 22.  
3. Set the telemetry input:  
-
-
-
TEL, see page 24  
DIM, see page 25  
Timer, see page 25  
4. Disable the LED status indicators, see LED Status Indicators  
on page 26.  
5. Disable remote control setup, see Disable Remote Control  
Setup on page 27.  
6. Restore the factory default settings, see Factory Default on  
page 27.  
Normal Operating Mode  
The only function of the Remote Control available during Normal Operating  
Mode is LED Status Indicators, see LED Status Indicators on page 26.  
 
21  
AXIS T90B Series  
Power Adjust  
The power output of the illuminator can be adjusted between five pre-set  
levels. Select the required light intensity by using the buttons below.  
1
2
3
4
5
20% of maximum  
40% of maximum  
60% of maximum  
80% of maximum  
100% of maximum  
Photocell Sensitivity  
Note  
When the photocell is disabled the illuminator will turn on and off  
from a telemetry input, regardless of ambient lighting conditions.  
 
22  
   
AXIS T90B Series  
There are three pre-defined levels to set the lux level threshold at which  
the photocell turns the illuminator on or off. Select the required sensitivity  
level by using the buttons below.  
1
2
3
4
Photocell disabled  
5 Lux On, 15 Lux Off  
10 Lux On, 30 Lux Off  
25 Lux On, 50 Lux Off  
Telemetry Input  
The telemetry input wires (orange and purple) are designed to be used  
with a remote switch or input from an alarm system, PIR detector, control  
room, video management system or camera output. The input signal can  
be volt-free or TTL.  
 
23  
AXIS T90B Series  
Volt-free input:  
TTL input:  
Non polarity sensitive  
Short circuit = Light on  
Orange = TTL +ve  
Purple = TTL -ve (GND)  
0 V = Light on  
3 V = Light off  
The telemetry input wires (orange and purple) are soldered together  
when shipped from the factory to simulate a volt-free input so that the  
illuminator automatically turns on and off via the photocell. Any remote  
input or switch should be connected to these wires. Snip the end of the  
cable and separate the cables to use with remote switch or input.  
Under normal operating conditions, a telemetry input will activate the unit  
only at night provided that the photocell detects low light conditions.  
However, if the photocell is disabled, a telemetry input will activate the  
unit regardless of ambient light conditions.  
The mode of operation is selected by using the remote control.  
The remote input can be used in conjunction with the illuminator in the  
following ways:  
1. TEL — see page 24  
2. DIM — see page 25  
3. TEL + TIMER — see page 25  
Telemetry - TEL  
Press the TEL button if the illuminator is to be turned on and off using  
a remote switch or input.  
The TEL input can be used in various ways:  
 
24  
 
AXIS T90B Series  
1. Turn the light on (night) and off (day) automatically via the  
photocell. This is the standard factory setting, no further  
action is required.  
2. Turn the light on and off from a remote switch or input.  
3. Used in conjunction with the Timer Function to turn the light  
on for a pre-defined period of time.  
Telemetry - DIM  
The remote dimming feature allows the brightness of the illuminator to be  
controlled remotely using the telemetry input wires. Use the DIM button  
to select this function.  
When the DIM function is selected, a telemetry input into the illuminator  
will vary the brightness up and down. When the telemetry input is first  
applied, it will start to dim the light and will continue to do so while the  
telemetry input is active. When telemetry input stops, the light level will  
stay where it was set. When the telemetry input is activated for a second  
time, the light will start to brighten. This will continue while the telemetry  
input is active. This activation and de-activation of the telemetry input  
will reverse the way the light is dimmed (dim down and dim up), to allow  
the user to set exactly the level required. Disable the DIM function by  
pressing the TEL button.  
After setting a specific light level using the DIM function, if DIM is disabled  
and TEL enabled, the last power level set when using the DIM function  
will be remembered and used by the system unless a new power adjust  
button is selected.  
Timer  
The timer function allows the illuminator to be triggered via a telemetry  
input and remain on for a pre-defined period of time. There are four  
pre-defined times and a timer disable function. To select timer function,  
first press and release the TEL button, then select the duration of the timer  
as shown below.  
 
25  
   
AXIS T90B Series  
If you wish to cancel the timer period and have the illuminator operate  
under standard telemetry conditions, press Timer Disabled.  
1
2
3
4
5
6
Timer disabled  
1 minute  
3 minutes  
10 minutes  
30 minutes  
TEL button  
LED Status Indicators  
This status indicator function can be switched on and off by pressing the  
STATUS button. This is the only button that has two states. It is possible  
for this function to be enabled even if Programming Mode has been  
disabled so the status of the illuminator can be checked at any time.  
 
26  
 
AXIS T90B Series  
Factory Default  
Note  
To activate this feature the button must be pressed continuously  
for 4 seconds. This is to avoid the possibility of activating this  
feature accidentally.  
Once the illuminator has been programmed, the settings will be stored in a  
non-volatile (stored) memory. These settings are saved and reloaded if the  
illuminator experiences loss of power. Press the RESET button to restore  
the illuminator back to the factory default settings.  
Disable Remote Control Setup  
Note  
To enable Programming Mode after remote setup has been  
disabled, the illuminator must be powered off for at least  
10 seconds. When turned on, the illuminator automatically  
re-enters Programming Mode.  
Disable remote setup once an individual illuminator has been programmed  
and is delivering the required operating performance. This will help  
to avoid tampering and the possibility of receiving commands when  
programming other illuminators in close proximity.  
Lock the illuminator settings by pressing the Disable Remote Setup button  
continuously for at least 4 seconds.  
If remote control setup is not disabled, the illuminator will remain in  
Programming Mode for a pre-determined time of 4 weeks. After 4 weeks,  
remote control setup will be automatically disabled.  
Troubleshooting  
Ensure all tests are undertaken by a qualified, trained engineer.  
Ensure safe working practices are followed at all times.  
 
27  
   
AXIS T90B Series  
Basics  
-
Check the LED status indicator. See LED Indicators.  
-
Check polarity of lamp connection: red = +ve,  
black = -ve  
-
-
Ensure power is 12-24 V AC or DC  
Ensure telemetry wires are shorted out or closed  
contact input (zero volt) is applied  
-
Check photocell is working. Cover photocell fully,  
light should turn on. It is sometimes difficult to  
see Infra-Red lamps working in high brightness  
conditions.  
-
Make sure that the power cable is within the  
specified distance.  
Lamp Test  
Note  
Use the appropriate multimeter depending on how  
the illuminator is being powered (AC or DC). Cover  
the photocell fully (or disable the photocell using the  
optional remote control) and make sure the telemetry  
wires are shorted out or closed contact input (zero  
volt) is applied.  
-
Check that the current is being drawn. The amount  
of current will depend on the power setting of the  
illuminator.  
Set up Camera, Lens and Illumination  
-
-
Make sure the power is set to maximum.  
Check the orientation of illuminator and make sure  
it is pointing in the correct direction  
-
Check angle of the diverging lens. A too narrow  
angle may cause hot spots and the aperture of the  
camera lens to close down. A too wide angle may  
cause insufficient light on the scene.  
 
28  
AXIS T90B Series  
Remote Control (optional accessory)  
-
Press the STATUS button to check the status of the  
remote control, see LED Status Indicators.  
-
Programming may be disabled. Turn the illuminator  
power off for at least 10 seconds and then turn the  
power on to enter Programming Mode.  
-
In bright sunlight conditions, the distance between  
the remote control and the illuminator may need  
to be reduced.  
-
-
-
-
Check the battery on the remote control (CR2025),  
replace if necessary.  
Make sure no other strong Infra-Red source is  
pointing at the remote receiver.  
Make sure there is a clear line of site between the  
illuminator and the remote control.  
Check the remote control battery.  
Technical Specifications  
Models  
AXIS T90B15 W-LED  
AXIS T90B25 W-LED  
AXIS T90B35 W-LED  
AXIS T90B20 IR-LED  
AXIS T90B30 IR-LED  
AXIS T90B40 IR-LED  
Supported cameras  
IR-LED: All Axis cameras with IR cut filter  
W-LED: All Axis network cameras  
 
29  
 
AXIS T90B Series  
Power  
Input Voltage: 12-24 V AC/DC  
AC Frequenzy: 50-60 Hz  
Cable length 2.5 m (8 ft)  
Power Consumption maximum light / 20% of  
maximum light / Standby mode:  
AXIS T90B15 W-LED: 12 W / 3 W / 0.15 W  
AXIS T90B25 W-LED: 24 W / 6 W / 0.15 W  
AXIS T90B35 W-LED: 48 W / 12 W / 0.15 W  
AXIS T90B20 IR-LED: 24 W / 6 W / 0.15 W  
AXIS T90B30 IR-LED: 48 W / 12 W / 0.15 W  
AXIS T90B40 IR-LED: 96 W / 24 W / 0.15 W  
Control technology  
Type  
Power level, Photocell sensitivity, Telemetry link  
for remote activation (if required), Timer  
IR-LED: 850 nm semi-covert  
W-LED luminous power:  
AXIS T90B15 W-LED: 733 lm  
AXIS T90B25 W-LED: 1452 lm  
AXIS T90B35 W-LED: 2840 lm  
Color temperature  
Angle  
5700 K (valid for W-LED versions only)  
10° without diverging lens  
With diverging lenses:  
35°  
60°  
80°  
120°*  
*Optional accessory  
 
30  
AXIS T90B Series  
Distance  
AXIS T90B20 IR-LED  
10°x10° - 120 m (394 ft)*  
35°x10° - 65 m (213 ft)  
60°x25° - 45 m (148 ft)  
80°x30° - 30 m (98 ft)  
120°x50° - 20 m (66 ft)**  
AXIS T90B30 IR-LED  
10°x10° - 220 m (722 ft)*  
35°x10° - 120 m (394 ft)  
60°x25° - 65 m (213 ft)  
80°x30° - 45 m (148 ft)  
120°x50° - 30 m (98 ft)**  
AXIS T90B40 IR-LED  
10°x10° - 310 m (1010 ft)*  
35°x10° - 170 m (551 ft)  
60°x25° - 112 m (367 ft)  
80°x30° - 70 m (230 ft)  
120°x50° - 65 m (213 ft)**  
AXIS T90B15 W-LED  
10°x10° - 50 m (164 ft)*  
35°x10° - 35 m (115 ft)  
60°x25° - 20 m (66 ft)  
80°x30° - 15 m (49 ft)  
120°x50° - 10 m (33 ft)**  
AXIS T90B25 W-LED  
10°x10° - 90 m (295 ft)*  
35°x10° - 55 m (180 ft)  
60°x25° - 30 m (98 ft)  
80°x30° - 20 m (66 ft)  
120°x50° - 15 m (49 ft)**  
AXIS T90B35 W-LED  
10°x10° - 150 m (492 ft)*  
35°x10° - 80 m (262 ft)  
60°x25° - 45 m (148 ft)  
 
31  
AXIS T90B Series  
80°x30° - 30 m (98 ft)  
120°x50° - 20 m (66 ft)**  
*No diverging lens  
**Optional accessory  
Casing  
Material: Polycarbonate  
IR-LED: Black  
W-LED: White and silver  
Display and indicators LED indicators  
Environment  
Mounting  
Outdoor  
Wall  
Ceiling  
Column  
Camera housing  
Approvals  
EN 55022 Class B, EN 55024  
EN 61547, EN 55015, EN 50130–4  
C-tick AS/NZS CISPR 22 Class B  
FCC Part 15 Subpart B Class B  
ICES–003 Class B  
KCC KN22 Class B, KN24  
IEC/EN 60598–1  
IEC/EN 62471 Risk group 2*  
IEC/EN 60529 IP66  
REACH, WEEE, CE  
*Valid only for IR-LED products  
Operating conditions  
-50 °C to 50 °C (-58 °F to 122 °F)  
10–100% RH (condensing)  
 
32  
AXIS T90B Series  
The size of the product shall be maximum  
Dimensions (HxWxL)  
(WxHxL):  
AXIS T90B15 W-LED: 75 x 100 x 64 mm (3 x  
4 x 2.5 in)  
AXIS T90B25 W-LED: 100 x 135 x 66 mm (4 x  
5 x 2.5 in)  
AXIS T90B35 W-LED: 135 x 180 x 68,2 mm (5 x  
7 x3.2 in)  
AXIS T90B20 IR-LED: 100 x 135 x 66 mm (4 x  
5 x 2.5 in)  
AXIS T90B30 IR-LED: 135 x 180 x 68,2 mm (5 x  
7 x3.2 in)  
AXIS T90B40 IR-LED: 279 x 223 x 68 mm (11  
x 9 x 3 in)  
Weight  
AXIS T90B15 W-LED: 600 g (1.3 lbs)  
AXIS T90B25 W-LED: 950 g (2.1 lbs)  
AXIS T90B35 W-LED: 1650 g (3.6 lbs)  
AXIS T90B20 IR-LED: 950 g (2.1 lbs)  
AXIS T90B30 IR-LED: 1650 g (3.6 lbs)  
AXIS T90B40 IR-LED: 4500 g (9.9 lbs)  
Included accessories  
Optional accessories  
3 diverging lenses:  
35° (pre-mounted)  
60°  
80°  
Power supply  
Mounting brackets  
AXIS T90B Remote Control  
Diverging lens (120° angle)  
Further Information  
Visit Axis learning center www.axis.com/academy for useful trainings,  
webinars, tutorials and guides.  
 
33  
AXIS T90B Series  
Warranty Information  
For information about Axis’ product warranty and thereto related  
information, see www.axis.com/warranty/  
 
34  
 
35  
Installation Guide  
AXIS T90B Series  
© Axis Communications AB, 2014  
Ver. M3.2  
Date: August 2014  
Part No. 59159  
 

3M Computer Monitor 11 81375 227 User Manual
Accell Bicycle Accessories Cardio Control User Manual
Ace Hardware Computer Monitor 3009701 User Manual
Actron Automobile Battery Charger CP7611 User Manual
Altinex Network Card MT101 114 User Manual
Alto Shaam Water System FI 23014 User Manual
Amcor Air Cleaner AM 80 User Manual
American Aldes Ventilation Hood RDF 8 8IP User Manual
AOC Flat Panel Television A27W231 User Manual
Beko Clothes Dryer DRVS 73 S User Manual