Audiovox Automobile Electronics PRO 9445FT User Manual

Model PRO 9445FT  
Installation Manual  
REMOTE KEYLESS ENTRY  
PRE-INSTALLATION NOTES:  
DIP SWITCHES :  
This unit incorporates three on - board dip switches for selection of optional features. They are;  
ON  
OFF  
Dip Switch #1  
Dip Switch #2  
Dip Switch #3  
Auto Lock/Unlock  
Passive Lock  
Passive Starter Inhibit  
No Auto Lock/Unlock  
Active Locks  
Active Starter Inhibit  
STARTERDISABLE:  
This system provides a transistorized output to control the starter cut feature.  
When the starter cut relay is installed, any time the doors are remotely locked, the vehicle's starting circuit is disabled.  
Additionally, when the passive starter cut feature is selected (dip switch #3 On), then 30 seconds after leaving the vehicle,  
the vehicle's starting circuit will be automatically disabled.  
CHANNEL2OUTPUT:  
This system provides an additional hardwire remote output to control an assortment of optional upgrades. This output  
is an independent channel from the transmitter, and is controlled by the (Option) button of the transmitter. It is a delayed  
ground pulse (300 mA maximum), and can be used to control;  
Optional Trunk Release Relay  
Optional Remote Starter  
Optional Window Roll Up  
Optional Garage Door  
AS-9256  
AS-9151N / AS-9075  
AS-9153  
AS-9154  
Additionally, if both transmitter buttons are designated, the remote transmitter has the capability of transmitting a third  
RF signal that can be used to operate a second vehicle equipped with a similar Pursuit alarm. By simultaneously  
pressing both the "Lock/Unlock" button along with the "Option" button, a third function can be operated.  
DOORLOCK/UNLOCKOUTPUTS:  
This system provides both (+) and (-) pulsed door lock outputs for direct connection to most OEM factory installed door  
lock control relays. These outputs have a maximum current capability of 300 mA, and external relays must be used for  
switching circuits requiring more than 300 mA, and with 4 or 5 wire polarity reversal door lock control circuits. The optional  
AS-9159 Door Lock Interface is available to simplify the wiring of these types of circuits.  
INSTALLATION OF MAJOR COMPONENTS:  
CONTROLMODULE:  
Selectamountinglocationinsidethepassengercompartment(upbehindthedash),andsecureitusingscrews,  
or cable ties.  
DO NOT mount the control module in the engine compartment, as it is not waterproof.  
DONOTmounttheunitorroutethewiringnearthesteeringshaft,asitmightbecomeentangled,preventingproper  
operationofthevehicle.  
1
 
DARK BLUE WIRE : CHANNEL 2 OUTPUT  
The dark blue wire pulses to ground via an independent RF channel from the keychain transmitter. This is a  
transistorized, low current (300 mA) output, and should only be used to drive an external relay coil or trigger inputs for  
optional devices.  
WARNING:Connectingthedarkbluewiretothehighcurrentswitchedoutputoftrunkreleasecircuitswilldamage  
the control module.  
Connect the dark blue wire to terminal 86 of the AS-9256 relay (or an equivalent 30 Amp. automotive relay), connect  
terminal 85 of the relay to a fused +12 VDC battery source,and wire the remaining relay contacts to perform the selected  
function of channel 2.  
GREY&BLACK2PIN(blue)CONNECTOR:VALETSWITCH  
Route the two conductor, blue connector from the valet switch to the control module, and plug it into the mating blue  
connector on the end of the module.  
RED&GREEN2PIN(white)CONNECTOR:DOORLOCKOUTPUTS  
These wires will provide either a pulsed ground output to the factory door lock control relay, or a pulsed +12 VDC output  
to the factory door lock control relay. In either case, the maximum current draw through these outputs must not exceed  
300 mA.  
3WIREGROUNDSWITCHEDDOORLOCKS  
TheRedwireprovidesa groundpulseduringlocking. ConnecttheRedwiretothewirethatprovidesalowcurrentground  
signal from the factory door lock switch to the door lock control relay.  
TheGreenwireprovidesagroundpulseduringunlocking. ConnecttheGreenwiretothewirethatprovidesalowcurrent  
ground signal from the factory unlock switch to the door unlock control relay.  
3WIREPOSITIVESWITCHEDDOORLOCKS  
The Red wire provides a positive +12 VDC pulse during unlocking. Connect the Red wire to the wire that provides a  
low current positive signal from the factory door unlock switch to the door unlock control relay.  
The Green wire provides a positive +12 VDC pulse during locking. Connect the Green wire to the wire that provides  
a low current positive signal from the factory door lock switch to the door lock control relay.  
4WIREPOLARITYREVERSALand5WIREALTERNATINGDOORLOCKCONTROLCIRCUITS  
In these applications, the AS-9159 Door Lock Interface (or equivalent 30 Amp. automotive type relays) must be used.  
Refer to the Audiovox Door Lock Wiring Supplement for proper connection to these types of door lock circuits.  
COMPLETING THE INSTALLATION:  
ANTENNA WIRE : Be sure to extend the thin Black antenna wire to it's full length, and cable tie in place where it cannot  
be damaged. Avoid wrapping this wire around major high current wiring looms.  
WIRE DRESSING : Always wrap the system's wires in convoluted tubing, or with a spiral wrap of electrical tape, and  
secure these looms along the routing using cable ties.  
OPERATION : Take a few moments to check off the appropriate option boxes in the owner's manual, and to fully explain  
the operation of the system to your customer.  
3
 
© 1998 Audiovox Corporation, Hauppauge, N.Y. 11788  
1-800-645-4994  
128-5393  
 

Activision Video Games PRT0000512
ADT Security Services Home Security System 3000EN User Manual
Allied Telesis Switch 8POE E User Manual
Allied Telesis Switch 48W User Manual
Alloy Computer Products Network Card BWS 136 User Manual
Alto Shaam Food Warmer 100 HSL BCS 2 User Manual
American Standard Outdoor Shower 2000500 User Manual
Audiovox Remote Starter APS 686T User Manual
Audiovox Speaker PL900SUB User Manual
Axor Indoor Furnishings 41250800 User Manual