Altec Lansing Intercom System LEF 3L User Manual

Special  
Order  
Products  
LEF-3L  
3-Call Master Station with Selective Control Capability (Door Release or Camera Call-up)  
Used with LE-D, LE-DA, LE-DL, LS-NVP/B Door Stations  
- SUPPLEMENT TO LEF INSTRUCTIONS -  
The LEF-3L is a compact, wall or desk mount master station able to selectively release a door or call up a camera.  
Used with any LE- or LS-series remote station, communication can be established with each station by selecting  
the channel on the master station. While the channel is selected, pressing the door release button (left of TALK  
button) will release only the associated door. When used for camera call-up, a relay closure will be maintained as  
long as a station is selected. The system can have up to four stations, in any combination of masters or door  
stations (e.g. 2 masters and 2 doors). Master-to-master communication is also a standard feature.  
(If communication between masters is not required, multiple LEF-3L's can be used to talk to 3 door stations.  
1
NAMES & FEATURES  
Speaker  
Microphone  
Station Call-in LEDs  
Station Selectors  
Occupied LED  
TALK Button  
OFF Button  
Voice  
Volume Control  
Door Release  
Button  
FEATURES:  
· Selective door release control  
· CCTV camera call-up capability  
· Single or multiple masters can be used in a system  
· Master to master communication in a multi-master system  
· Single talkpath, with push-to-talk operation at master, and hands free communication  
at sub station  
· Large variety of sub stations available  
- Surface or flush mount, with or without privacy (LE-A, LE-AN, LE-B, LE-BN)  
- Weather resistant door stations (LE-D, LE-DA, LE-DL)  
- Vandal proof sub station (LS-NVP/B, and optional SBX-DGV surface mount box)  
· Subs call in with momentary tone and LED, remaining lit for approximately 20 seconds  
· Selective calling to sub stations  
Pg. 1  
 
3
WIRING DIAGRAMS  
1 LEF-3L, 3 Door Stations -  
Shown with door release relays  
LEF-3L  
LE-D/  
LE-DA  
LE-D/  
LE-D/  
LE-DA  
LE-DA  
1
2
3
E
-
1
NOTE:  
1
When running 2 conductors homerun  
to each sub (single master system  
only), leave jumper attached between E  
& - on master and door stations.  
Otherwise, remove jumpers and use  
separate wires for E and - terminals.  
1
E
-
PS-12C  
E
-
E
-
-
+
+
C
R
12V DC when "key" button is pressed  
AC Transformer  
Y
Momentary dry closure when station is  
A
RY-PA  
A
Wht  
Brn  
Red  
Org  
selected and "key" button is pressed.  
Connect to door strike & power.  
Blk  
Yel  
Dr. #1  
RY-PA  
Dr. #2  
Blk  
Yel  
A
A
RY-PA  
Dr. #3  
Yel  
Blk  
2 LEF-3L, 2 Door Stations  
Shown with door release relays  
Master-to-Master communication shown using channel 3  
LE-D/  
LEF-3L  
LEF-3L  
LE-DA  
LE-D/  
LE-DA  
1
2
3
C
E
-
1
2
C
3
E
-
1
1
PS-12C  
E
-
E
-
Momentary dry closure when station is  
selected and "key" button is pressed.  
Connect to door strike & power.  
A
-
+
+
+
R
Y
R
Y
AC Transformer  
Wht  
Wht  
RY-PA  
Dr. #1  
A
Blk  
Yel  
A
Brn  
Red  
Org  
Brn  
Red  
Org  
RY-PA  
Dr. #2  
Yel  
Blk  
3 LEF-3L, 3 Door Stations  
No Master to Master Communication  
Shown with door release relays  
LE-D/  
LE-DA  
LEF-3L  
LEF-3L  
LEF-3L  
LE-D/  
LE-DA  
1
2
3
1
2
3
1
2
3
1
LS-NVP/B  
Red  
1
C
E
C
E
C
E
PS-12C  
Blk  
Grn  
E
-
E
-
-
+
R
-
-
+
R
-
+
+
12V DC when "key" button is pressed  
R
AC Transformer  
Y
Y
Y
Wht  
Brn  
Red  
Org  
Wht  
Brn  
Red  
Org  
Wht  
Brn  
Red  
Org  
RY-PA  
Dr. #1  
A
Blk  
Yel  
RY-PA  
Dr. #2  
Blk  
Yel  
A
A
RY-PA  
Dr. #3  
Yel  
Blk  
Momentary dry closure when station is  
selected and "key" button is pressed.  
Connect to door strike & power.  
A
Pg. 3  
 
3
WIRING DIAGRAMS (Cont.)  
1 LEF-3L, 2 Door Stations -  
Shown with both Door Release and CCTV Camera Call-up relays  
LE-D/  
LE-D/  
LEF-3L  
LE-DA  
LE-DA  
NOTE:  
1
2
3
C
E
-
1
This diagram shows separate E &  
- wires. In single master system  
only, one wire can be used for E/-  
when jumper remains attached  
between E & - on master and  
door stations.  
1
PS-12C  
E
-
E
-
-
+
R
Y
+
RY-PA  
Cam. #1  
RY-PA  
Cam. #2  
B
Blk  
Yel  
Blk  
Yel  
B
* Diode  
* Diode  
RY-PA  
Dr. #1  
RY-PA  
Dr. #2  
Wht  
Brn  
Red  
Org  
A
Momentary dry closure when station is  
selected and "key" button is pressed.  
Connect to door strike & power.  
Blk  
Yel  
Blk  
Yel  
A
A
B
Constant closure as long as station is  
selected.  
* Diode: 1N4001 value.  
Required for door strike relay  
only when 2 relays are used  
on any one channel.  
4
OPERATIONS & SPECIFICATIONS  
OPERATION:  
1. Pressing the call button at the door station will activate a tone, plus light the red channel LED indicator at the  
master. The tone will be momentary, and the light will remain activated for approximately 20 seconds.  
2. The person at the master station answers the call by pressing the selector button with the lit LED. If the LED has  
already gone out, the call can still be answered by pressing the selector button.  
3. Communication at the master station is "press-to-talk, release-to-listen". Communication at the door station is  
hands free.  
4. If the "Camera Call-up" feature is included, the associated relay will provide a maintained closure as long as the  
station is selected at the master.  
5. With communication established to a door station, pressing the door release button (marked with key symbol, left  
of TALK button) will activate the door release mechanism at the corresponding door. The door release button  
will  
be non-functional if a station button is not pressed.  
6. When the conversation is completed, the OFF button must be pressed to disengage the call.  
NOTE:  
The LEF-3L does not have the "privacy feature", and also cannot send a call tone to the remote stations.  
SPECIFICATIONS:  
Power Source:  
12V DC at master. Use PS-12C.  
Communication Output: 800mW @ 20 ohms (receive); 500mW @ 20 ohms (transmit)  
Communication:  
Calling:  
Push-to-talk, release-to-listen at master station. Hands free at sub station.  
Master to sub: By voice  
Sub to master: Call tone and LED  
Wiring:  
2 common plus 1 individual per sub, looped; or 3 conductors homerun from each sub.  
2 conductors homerun from each sub in a single-master system only.  
Use Aiphone #822202 or #821802 ( 2 cond., 22 or 18AWG), or #822203 (3 cond. 22AWG)  
12 conductors between master stations. Use Aiphone #822212.  
Shielded cable is strongly recommended.  
Wiring Distance:  
650' with 22AWG; 1,600' with 18AWG.  
Dimensions (HxWxD): 7-1/16" x 5-5/8" x 2-3/16"  
RY-PA Contact Rating: 1A, 110V AC or 24V DC  
TOLL FREE TECHNICAL SUPPORT:  
Aiphone Communication Systems  
1700 130th Ave. N.E.  
Bellevue, WA 98005  
(425) 455-0510  
(800) 692-0200  
TOLL FREE FAX LINE:  
(800) 832-3765  
LEF-3L Instr.  
0101BKJD  
FAX (425) 455-0071  
 

2nd Ave Coffeemaker D 490 Zoom User Manual
3Com Network Card 3C975 User Manual
Adesso Computer Keyboard ACK 730 User Manual
AEG Washer Dryer 52630 User Manual
Agilent Technologies Portable Generator 81250 User Manual
Alcatel Carrier Internetworking Solutions Switch 1850 TSS 5 User Manual
Allied Telesis Switch AT 9924SP 30 User Manual
Altinex Network Card MT115 110 User Manual
American Sensor Carbon Monoxide Alarm NG401 User Manual
Barco Laser Pointer 26 0405000 00 User Manual