Airlink101 Switch AGSW1600 User Manual

Quick Installation Guide  
16-Port 10/100/1000Mbps  
Green Switch  
Model# AGSW1600  
Ver. 1A  
 
Introduction  
Congratulations on your purchase of the 16-Port  
10/100/1000Mbps Green Switch! It is an easy-installed  
network switch which helps you to extend your network  
structure quickly and reliably. The 16-Port 10/100/1000Mbps  
Green Switch is designed for energy saving, easy installation  
and high performance in an environment where network  
traffic and the number of users increase continuously. You  
can add other Ethernet devices like computers, IP cameras,  
and Network Attached Storage (NAS) onto your network  
quickly and easily. The Green EEE (Energy Efficient Ethernet)  
technology of AGSW1600 automatically reduces the power  
usage when a connected port is detected inactive (idle or  
cable-unplugged) and intelligently allocates less power for a  
port that connects with an Ethernet cable shorter than 20m  
(66 ft)*.  
Before you begin the installation, please check the items of  
your package:  
Package Contents:  
16-Port 10/100/1000Mbps Green Switch  
Power Cord  
Quick Installation Guide  
Brackets and Screws  
2
 
Section 1  
Hardware Description  
1.1 Hardware Interface  
16-Port 10/100/1000Mbps auto-negotiation RJ45 Ports  
All ports support auto MDI/MDIX, no need to use  
cross-over cables  
1.2 Panel  
1.2.1 Front Panel  
The front panel of the Switch consists of LED indicators, and  
16 10/100/1000Mbps ports. The figure below shows the front  
panel of the Switch.  
Figure 1-1 Front Panel view of the Switch  
10/100/1000Mbps Ports (Port 1~16): These ports support  
10/100/1000Mbps, and can operate in Half/Full Duplex  
transfer modes. These ports also support automatic  
MDI/MDI-X crossover detection, giving true “plug and  
play” capability.  
LED Indicators: Comprehensive LED indicators display  
the status of the Switch and the network (see Section  
1.2.3).  
3
 
1.2.2 Rear Panel  
Figure 1-2 Rear Panel view of the Switch  
AC Power Connector: Supports AC 100~240V, 50~60Hz.  
NOTICE:  
Do not cover or put anything on or surrounding the Switch  
while the Switch is operating.  
1.2.3 LED indicators information  
The front panel LEDs provide instant status feedback and  
help monitoring and troubleshooting when needed.  
Figure 1-3 Front Panel view of the Switch  
4
 
POWER: Power Indicator  
Status  
LED  
Color  
Solid  
Blinking  
Off  
The Switch is  
power-on  
POWER  
Green  
N/A  
No power  
Port 1~16 10/100/1000Mbps Status LEDs  
Status  
LED  
Color  
Solid  
The  
Blinking  
Off  
respective  
port is  
The port is  
LINK/  
ACT  
successfully  
transmitting or  
Green  
connected to receiving data  
No link  
10/100M  
the  
at  
10/100Mbps  
Ethernet  
network  
10/100Mbps  
Status  
LED  
Color  
Solid  
The  
Blinking  
Off  
respective  
port is  
The port is  
LINK/  
ACT  
transmitting or  
Blue  
connected to receiving data  
No link  
1000M  
the 1000Mbps  
Ethernet  
at above  
100Mbps  
network  
5
 
Section 2  
Installing the Switch  
The site where you place the Switch may greatly affect its  
performance.  
2.1 Installation  
Please follow the guidelines below to install the Switch:  
Please install the Switch in a fairly cool and dry place.  
Please refer to the Technical Specifications for the  
acceptable temperature and humidity operating  
ranges.  
Please install the Switch on a sturdy, level surface that  
can support its weight.  
When connecting the power cord to the Switch and the  
power outlet, the distance should be no more than  
182cm.  
Please leave at least 10cm (about 4 inches) of space  
at the front and rear of the Switch for ventilation.  
2.2 Desktop or Shelf Installation  
When installing the Switch on the desktop or shelf, please  
attach the rubber feet to the Switch. Peel off the protective  
paper on the pads and attach them to the bottom of the  
Switch (one at each corner).  
6
 
2.3 Rack Installation  
The Switch is rack-mountable and can be installed on an EIA  
11-inch equipment rack. To do this, first install the mounting  
brackets on the Switch’s side panels (one on each side),  
secure them with the included screws, and then use the  
screws provided with the equipment rack to mount the  
Switch.  
2.4 Power on the Switch  
The Switch has a universal power supply ranging from 100V  
to 240V AC, 50 ~ 60Hz power source. The AC power  
connector is located at the rear of the unit. The switch’s  
power supply will adjust to the local power source  
automatically.  
7
 
Section 3  
Connecting the Switch  
This section describes how to connect the Switch to your  
10/100/1000Mbps Ethernet network.  
Your network device (i.e. computer, switch, IP Camera, VoIP)  
can be connected to any port of the Switch via a two-pair  
UTP Category 5 Cable. If the LED indicators do not light up  
after making a proper connection, check your network device,  
the cable, the Switch conditions and connections.  
8
 
Section 4  
Troubleshooting  
1. Power LED is not lit  
Check if the power adapter is properly connected to the  
power outlet. Make sure the power jack is firmly plugged  
into the power socket of the switch.  
2. Link/Activity is not lit when connect to 10/100/1000Mbps  
device  
Check the power switch of the network device attached to  
the switch; make sure it is turned ON.  
Check the network cable; make sure it is properly  
connected to the switch and the network device.  
Check the network cable; make sure the UTP cables  
comply with the specifications described in Section 2.  
9
 
Section 5  
Technical Specifications  
Standards  
IEEE 802.3 10BASE–T, IEEE 802.3u 100BASE–TX,  
IEEE802.3ab 1000BASE-T Gbit. IEEE 802.3x Flow  
Control and IEEE 802.3az(EEE – Energy Efficient  
Ethernet)  
Network Cables  
Ethernet (10Base-T): Cables: 2-pair UTP Cat. 3, 4, 5,  
Twisted Pair (UTP). Up to 100m  
Fast and Giga Ethernet (100/1000Base-T): 2-pair UTP  
Cat. 5, Twisted Pair (UTP). Up to 100m  
Ports  
16 x 10/100/1000Mbps Auto-Negotiation RJ45 Port  
Access Method  
CSMA/CD  
Transmission Method  
Store and Forward  
MAC Address Table  
8K  
Jumbo Frame  
9216-byte jumbo packet length forwarding at wire speed  
Data Transfer Rate**  
Ethernet: 10/20Mbps – Half/Full-Duplex  
Fast Ethernet: 100/200Mbps – Half/Full Duplex  
Giga Ethernet 1000/2000Mbps – Half/Full Duplex  
10  
 
LED  
Power: Green  
Link/Activity: 1000M(Blue), 10/100M(Green)  
Rack Mount  
11-Inch Rack-Mountable with mounting kits  
Dimensions  
280x165x45mm (LxWxH)  
Weight  
1200g  
Physical and Environmental  
Power Input: 100~240V AC, 50~60Hz  
Operation Temperature: 0 °C ~ 40°C(32 ~ 104°F)  
Storage Temperature: -20°C ~ 70°C(-4 ~ 158°F)  
Humidity: 5% ~ 90% RH, non-condensing  
Certification  
FCC, CE  
11  
 
Section 6  
Technical Support  
Toll-Free: 1-888-746-3238*  
* Free Voice Technical Support is only available within the hardware warranty  
(1-Year Limited Warranty from the date of purchase). Customer is required to  
provide invoice as purchase evidence.  
**Network conditions and environmental factors as well as network overhead can  
lower actual data throughput rate.  
Copyright © 2011 AirLink101®. All rights reserved. AirLink101, the stylized  
AirLink101® logo, specific product designations, and all other words and logos  
that are identified as trademarks and/or service marks are, unless noted  
otherwise, the trademarks and service marks of AirLink101®. All other product or  
service names are the property of their respective holders. AirLink101 products  
are protected under numerous U.S. and foreign patents and pending applications,  
mask work rights, and copyrights.  
12  
 

Aastra Telecom Telephone 1600IP User Manual
Acer Tent AC701 User Manual
Addonics Technologies Network Card ADN1GPX User Manual
Allied Telesis Switch 8PS User Manual
AO Smith Water Heater AOSRG45900 User Manual
Audiovox Automobile Alarm PRO 9243 User Manual
Banner American Products Stud Sensor S18M User Manual
BC Speakers Portable Speaker DE 600 User Manual
BC Speakers Speaker 15PLB76 User Manual
Behringer DJ Equipment DCX2496 User Manual