Adder Technology Switch 8XM User Manual

ePowerSwitch 8XM Master  
High security ePowerSwitch  
supports https (SSL) protocol  
ePowerSwitch 8XM Master is an enhanced power distribution and control unit that enables remote power  
management of 8 devices (extendable up to 136) over Intranet or Internet.  
This high security device uses HTTPS protocol with Web browsers that support SSL version 2 or 3.  
It includes also many monitoring functionalities and supports SNTP and SMTP protocol.  
Advanced Security  
For your security, account access and data transfer are  
Features  
encrypted with SSL Technology.  
Remote Power Management  
Each power outlet can be turned On/Off or restarted over  
IP. The number of controlled outlets can be extended up  
to 136 by cascading 16 Satellite models.  
Multiple concurrent users  
Allows multiple concurrent user access to the Master and all  
Satellites. Each user has access to control his designated  
power outlets.  
Two separate AC Power Inputs  
To improve the security and increase the total current  
load the ePowerSwitch 8XM supports dual Power Inputs  
(up to 10 Amps each). The first one provides power for  
outlets 1 to 4 and the second one for outlets 5 to 8. This  
feature is ideal for power management of servers with  
redundant power supplies.  
DHCP client  
Reduces configuration management.  
Scheduler for Time-Controlled Applications  
This time-controlled function lets you control Power Outlets and  
dry Contacts and also allows to send Emails.  
IP device monitoring  
Power Outlet Extension  
Enables to monitor IP devices using PING and Scan functions  
with automatic reboot in case of lock-up of the monitored  
device.  
Up to 16 ePowerSwitch Satellites can be connected to a  
Master to control up to 136 Power Outlets.  
Power Outlet Grouping  
Temperature and Humidity monitoring  
Enables to group individual outlets from the Master and  
different Satellites. Ideal to control multiple power supply  
servers & devices with a single command.  
This function lets you monitor temperature and humidity in  
racks or server rooms. If thresholds are exceeded, Power  
Outlets can be automatically switched off, dry contacts  
controlled and Email sent.  
Power-up Sequencing:  
Avoids the risk for a power in-rush to blow a fuse or circuit  
breaker in the data center.  
Improved log file reporting  
More information enables to help in troubleshooting.  
Restart Delay  
Programmable Labels  
A 32-character label can be attributed to each connected  
device to avoid confusion during operation.  
This delay, which applies to the restart activity at all  
power outlets, can be chosen between 5 and 60 seconds  
between off/on.  
Easy Configuration  
Access and accounts  
Full configuration can be performed through the LAN using a  
very convenient Windows tool (can be disabled) or through the  
Web using the Web GUI.  
The administrator password allows configuration and  
control of all power outlets. The administrator also can  
create up to 255 user accounts with access rights only to  
designated outlets.  
Technology House - Trafalgar Way Bar Hill - Cambridge - UK CB3 8SQ  
Tel:+44 (0)1954 780044 - Fax:+44 (0)1954 780081  
 

Acer Computer Monitor AL2032 User Manual
AEG Dishwasher ESL 63010 User Manual
Airlink101 Security Camera AICN1500W User Manual
Airlink Network Card AWLL6080 User Manual
Alto Shaam Water System FI 23014 User Manual
American Standard Plumbing Product 7222712 User Manual
AOC Flat Panel Television LE42H09P User Manual
Atlantis Land Switch A07 ES4704BD User Manual
Bacharach Carbon Monoxide Alarm MGC200 User Manual
Behringer Music Pedal CC300 User Manual