ITE
Indirect calorifier-solar
ITE - 300/400/500/600/750/1000
Indirect water heater (calorifier) for solar applications
• Single-wall spiral heat exchanger • PermaGlas Ultra Coat
second-generation glass coating technology prevents corrosion
• ITE 400-1000: Insulated ring base • Insulated access cover for
comprehensive waterside maintenance • Replaceable magnesium
anode • Options: Flexible magnesium anode for installation in
confined areas • Powered anode for reduced maintenance
requirements • Temperature and pressure valve with stainless
steel spring set to 95°C and a maximum water pressure of 7 bar
• Analogue temperature gauge (0-120°C) • Electric element heat
packs (3 - 36 kW) • Optional ancillaries: unvented kits
• Destratification pump kit
Innovation has a name.
ITE
Dimensions
ITE 400-1000
2
8
A
D
G
H
M
N
O
P*
P**
R
1705
720
255
771
70
1652
115
330
897
500
1096
1362
-
2040
720
255
915
70
1990
115
330
1029
500
1288
1700
-
1835
910
304
906
85
1797
180
412
1062
649
1236
1476
-
2030
910
305
967
85
1992
180
413
1113
650
1297
1627
-
2000
1060
345
947
95
1962
180
447
1087
700
1397
1602
-
9
7c
7b
S
T
U
Ob
1
2
3
4
7
8
8
Cold water
Hot water
Inlet coil
Outlet coil
Connection
Anode connection Rp11/4
R2
R2
Rp1
Rp1
Rp3/4
R2
R2
Rp1
Rp1
Rp3/4
Rp11/4
R21/2
R21/2
Rp1
Rp1
Rp3/4
Rp11/4
R21/2
R21/2
Rp11/4
Rp11/4
Rp3/4
R21/2
R21/2
Rp11/4
Rp11/4
Rp3/4
4
Rp11/4
Rp11/4
Connection (female) 1”-111/2 npt 1”-111/2 npt 1”-111/2 npt 1”-111/2 npt 1”-111/2 npt
7a
10 Anode connection
-
Oa
Dimensions in mm. All ITE calorifiers receive a three years
warranty on the tank and one year on parts.
3
1
Dimensions for ITE 1500-3000 available upon request.
*
Upper cleaning and inspection opening
** Lower cleaning and inspection opening
D
ITE
Installation diagrams
1
3
4
5
6
9
Pressure reducing valve
T&P valve
12
T
ITE 400-1000 unvented
11
Stop valve
B
Non-return valve
Circulation pump
Drain valve
14
14
14
11 Isolating valve
12 Temperature gauge
14 Hot water outlets
15 Expansion relief valve
16 Expansion vessel
17 Three way valve
18 Water tank
3
F
19 Float valve
A
B
C
F
Cold water
C
Hot water
4
5
6
4
Return circulation
Primary flow
16
G
A
G
E
Primary return
Over flow pipe
Expansion vent pipe
15
A
H
5
1
4
9
A.O. Smith unvented system kits utilise combination valves.
Further installation and connection details can be found in
the Installation & Commissioning Manual.
H
ITE 400-1000 vented
17
For the parts numbers of components please refer to the
“Maintenance and accessories” chapter.
A
E
19
4
18
12
T
11
B
14
14
14
3
F
C
4
5
6
4
G
4
9
|