BTH-120
through
BTH-500
UP TO 96% THERMAL EFFICIENCY,DIRECT VENT
The A.O. Smith Cyclone Xi family of products represents the industry’s most technologically
advanced commercial water heaters. The innovative Cyclone Xi design takes performance to
its highest level with efficiencies of 95% and 96%. Models are available from 120,000 BTUs
and now up to 500,000 BTUs. In addition, the Cyclone Xi features an Intelligent Control
System making it the smartest water heater in the industry.
Cyclone Xi provides outstanding hot water output, with dramatic savings on operating costs
compared to units with standard 80% efficiency. A.O. Smith’s leading-edge engineering
delivers conventional power-vent or sealed combustion power direct-vent versatility, low NOx
emissions and excellent space-saving characteristics. Powered anodes, standard on all
Cyclone Xi models, provide superior tank protection for years of trouble free operation.
INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY
• Exclusive A.O. Smith designed control
• Provides detailed water heater status information
• Precise temperature control
• Built-in diagnostics
• Run histrory information
SUBMERGED COMBUSTION CHAMBER,
WITH HELICAL HEAT EXCHANGER COIL
• Positioned in center of tank, surrounded by water to virtually
eliminate radiant heat loss from chamber
• Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal
force to maximize efficiency of heat transfer to water in tank
• Spiral heat exchanger prevents scale and sediment from forming on
water-side surface, which can reduce energy efficiency over time
POWERED ANODES STANDARD ON ALL MODELS
• Provides long-lasting tank protection in varying water conditions
• Does not require maintenance or inspection
Approved,
Rule 1146.2 Low NOx for
California and Texas
®
™
PERMAGLAS ULTRA COAT GLASS LINING
• Exclusive process provides superior protection against corrosion
BTH-120-250
• Both sides of heat exchanger coil are lined for protection against flue gas
condensate inside coil
MECHANICAL VENTING VERSATILITY
• Conventional power-venting or sealed combustion direct venting
• Vents vertically or through sidewall
• Direct-vent intake and exhaust pipe can terminate separately outside building,
or through single opening, using concentric vent assembly
BTH-300-500
• Uses inexpensive PVC, CPVC or ABS pipe for intake and exhaust
HIGH EFFICIENCY PRE-MIX POWERED BURNER
• Down-fired pre-mix burner provides optimum efficiency and quiet operation
• Top-mounted burner position prevents condensation from affecting burner operation
Page 1 of 4
ACGSS02407
December 2007R
BTH-120-250
WATER OUTLET
1 1/2˝ NPT
A
B
D
G
C
BTH-300-500
E
F
INSTALLATION CLEARANCES
MAXIMUM EQUIVALENT
VENT LENGTH:
GAS VALVE PIPING
Sides
0˝
0˝
BTH-120
BTH-150
BTH-199
BTH-250
BTH-300
BTH-400
BTH-500
1/2˝ NPT
3/4˝ NPT
BTH-
120 – 250
using 3˝ pipe:
Front
50 ft.
Rear
0˝
3/4˝ NPT
3/4˝ NPT
1 1/4˝ NPT
1 1/4˝ NPT
1 1/2˝ NPT
BTH-
120 – 250
using 4˝ pipe:
120 ft.
Top
1.5˝
To Combustibles*
• Approved for combustible floors
0˝
BTH-
using 3˝ pipe:
300 – 500 not applicable
BTH-
300 – 500
using 4˝ pipe:
70 ft.
DIMENSIONS AND SHIPPING WEIGHTS
DIMENSIONS
SHIP WEIGHT
SHIP WEIGHT
STD
ASME
MODEL
A
B
C
D
E
F
G
INCHES/CM INCHES/CM INCHES/CM INCHES/CM INCHES/CM INCHES/CM INCHES/CM
LBS/KG
LBS/KG
55.5/141
44.5/113
35/88.9 27.75/70.5 7.5/19.1
6.3/16
6.3/16
6.3/16
47/119.4
68/172.7
72/182.9
460Lbs/208.7Kg 490Lbs/222.2Kg
555Lbs/251.7Kg 595Lbs/269.9Kg
555Lbs/251.7Kg 595Lbs/269.9Kg
BTH-120
BTH-150
75.5/191.8 64.5/163.8 55.5/141 27.75/70.5 7.5/19.1
75.5/191.8 64.5/163.8 55.5/141 27.75/70.5 7.5/19.1
BTH-199, 250
75.5/191.8 64.5/163.8 50.77/129 33.12/84.1
8/20.3
4.86/12.3 67.25/170.8
N/A
855Lbs/408.2 Kg
BTH-300, 400, 500
Water connections: 1-1/2˝
Page 3 of 4
ACGSS02407
UP TO 96% THERMAL EFFICIENCY,DIRECT VENT
RECOVERY CAPACITY
U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
INPUT
BTUH
Fº
Cº
30 Fº 40 Fº 50 Fº 60 Fº 70 Fº 80 Fº 90 Fº 100 Fº 110 Fº 120 Fº 130 Fº 140 Fº
17 Cº 22 Cº 28 Cº 33 Cº 39 Cº 44 Cº 50 Cº 56 Cº 61 Cº 67 Cº 72 Cº 78 Cº
TYPE OF
MODEL
Thermal
Approx.
Capacity
GAS
Efficiency
KW
35
120,000
150,000
199,900
250,000
300,000
399,900
499,900
60 U.S. Gal GPH 461
227 Litres LPH 1744 1308 1046 872
100 U.S. Gals. GPH 576 432 345 288
379 Litres
100 U.S. Gals. GPH 767
379 Litres
100 U.S. Gals. GPH 960
379 Litres
130 U.S. Gals. GPH 1164 873
492 Litres
130 U.S. Gals. GPH 1552 1164 931
492 Litres LPH 5875 4406 3525 2938 2518 2203 1958 1759 1602 1469 1356 1259
130 U.S. Gals. GPH 1919 1439 1151 959 822 720 640 576 523 480 443 411
492 Litres LPH 7263 5447 4358 3631 3113 2724 2421 2179 1981 1816 1676 1556
345
276
230
197
747
247
173
654
216
817
288
154
581
192
726
256
138
523
173
654
230
871
288
126
476
157
594
209
792
262
115
436
144
545
192
726
240
908
291
106
402
133
503
177
670
221
838
269
99
NATURAL/
PROPANE
BTH 120
BTH 150
BTH 199
BTH 250
BTH 300
BTH 400
BTH 500
95%
95%
95%
95%
96%
96%
95%
374
123
467
164
622
206
778
250
NATURAL/
PROPANE
44
LPH 2179 1635 1308 1090 934
575 460 384 329
NATURAL/
PROPANE
58
LPH 2904 2178 1743 1452 1245 1089 968
720 576 480 411 360 320
NATURAL/
PROPANE
73
LPH 3632 2724 2179 1816 1557 1362 1211 1044 991
699 582 499 436 388 349 318
NATURAL/
PROPANE
88
LPH 4406 3304 2644 2203 1888 1652 1469 1322 1201 1102 1017 945
776 665 582 517 465 423 388 359 332
NATURAL/
PROPANE
117
NATURAL/
PROPANE
146
Recovery capacities are based on heater performance at 95% and 96% thermal efficiency.
Add "A" to model number when ordering ASME. Optional on 120 - 250 models. Standard on 300 - 500 models.
Maximum gas supply pressure for 120 - 250: 10.5" w.c. natural gas 14" w.c propane. Maximum gas supply pressure for 300-500 10"w.c. natural gas 13" w.c. propane.
Manifold pressure: 4" w.c. natural gas 10" w.c. propane. Electrical requirements: 120 VAC, Blower 2.2 Amps FL, Igniter 4.0 Amps.
SUGGESTED SPECIFICATION
(Natural or Propane) gas water heater(s) shall be A. O. Smith Cyclone Xi model # _________ or equal, with up to 96% thermal efficiency, a storage capacity of
______ gallons, an input rating of __________ BTUs per hour, a recovery rating of ___________ gallons per hour (gph) at 100° F riseand a maximum hydrostatic
working pressure of 160 PSI. Water heater(s) shall: 1. Have seamless glass-lined steel tank construction, with glass lining applied to all water-side surfaces
after the tank has been assembled and welded; 2. Have a spiral-shaped heat exchanger placed entirely inside the tank, which shall be glass-lined to protect
against acidic flue gas condensate; 3. Have foam insulation and an ASME-rated temperature and pressure relief valve; 4. Have a down-fired power burner
designed for precise mixing of air and gas for optimum efficiency, requiring no special calibration on start-up; 5. Be approvedfor 0˝ clearance to combustibles.
Heater shall be supplied with maintenance-free powered anode.
The control shall be an integrated solid-state temperature and ignition control device with integral diagnostics, graphic userinterface, fault history display, and
shall have digital temperature readout.
The water heater(s) shall: 1. Be design-certified by UL (Underwriters Laboratories), according to ANSZ21.10 standards governingstorage-type water heaters; 2. Meet
ASHRAE/IESNA 90.1-1999; 3. Be design-certified by Underwriters Laboratories for 180° F (62° C) water; 4. Meet SCAQMD Rule 1146.2 for low-NOx emissions.
For conventional-vent specification: The BTH-120 - 250 water heater(s) shall be suitable for venting in 3˝ PVC pipe for a total equivalent distance of 50 ft
and 4˝ PVC pipe for a total equivalent distance of 120 ft.
The BTH-300 - 500 water heater(s) shall be suitable for venting only in 4˝ PVC pipe, for a total equivalent distance of 70 ft.
For sealed-combustion direct-vent specification: The BTH-120 - 250 water heater(s) shall be suitable for venting with (3˝ or 4˝) _______ diameter PVC pipe for a
total equivalent distance of (50 ft or 120 ft) ________ feet. [Alternative venting: the heater(s) shall be suitable for sealedcombustion direct venting using a (3˝ or 4˝)
________ diameter PVC exhaust pipe for a total distance of (50 ft or 120 ft) ________ equivalent feet of vent and (50 ft or 120ft) _______ equivalent feet of intake.]
The BTH-300 - 500 water heater(s) shall be suitable for sealed combustion direct-vent using only 4˝ diameter PVC pipe and 4˝ diameter PVC exhaust pipe for a
total equivalent distance of 70 ft.
Operation of the water heater(s) in a closed system where thermal expansion has not been compensated for (with a properly sizedthermal expansion tank) will
void the warranty.
For Technical Information and Automated Fax Service, call 800-527-1953.
A. O. Smith reserves the right to make product changes or improvements without prior notice.
Page 4 of 4
ACGSS02407
December 2007R
Printed in U.S.A.
|