FLUXPOWER
HPS
400-500-600-800 KVA
3-phase UPS
High power solution for large,
mission-critical systems
Flexible and smart
High efficiency reduces overall cost
of ownership
The innovation and design of the Fluxpower HPS high
power UPS has resulted in the unit being the most
technologically advanced in its class.
Fluxpower HPS has a new Wise ECO function which enables a
total operating efficiency of between 95 % and 98 %. This mode,
referred to as “Intelligent ECO mode”, significantly reduces
the utility costs associated with operating a device of this type.
Moreover, this increase in efficiency results in the production
of less waste heat, minimizing cooling / air-conditioning costs.
This represents a double saving to the energy conscious user.
It delivers an incredible combination of low input current
distortion, unity input power factor and high overall efficiency.
These advances in design offer numerous benefits, including
lower running costs and substantially increased reliability.
The Wise ECO function uses continual monitoring techniques to
review the input characteristics of the supply. This means that if the
Low THDi and power factor performance
The Fluxpower HPS model UPS uses a completely new IGBT input supply line drops or fluctuates outside of acceptable conditions the
rectifier design, encompassing an advanced PFC (Power Factor
Control) which is capable of keeping input current THDi (Total
Harmonic Distortion) at a level of less than 3 % and input power
factor within 1 % of unity, even when only small loads are applied.
UPS uses the internal inverter to support the load. This is achieved
through a fast, fully static transition from VFD to VFI mode.
The key benefits are that the UPS is compatible with the
upstream source, the mains or any kind of generator and the
transfer of power between source and load is more efficient.
This results in a saving in terms of scale of sources, cables
and protective devices.
3
FLUXPOWER HPS
FEATURE RICH INTELLIGENCE
Easy installation,
operation and
maintenance
Parallel control is distributed
between all units and
Fluxpower HPS can easily be
sited within areas no wider than
1200 mm, and can be installed
close to walls or other cabinets
as cooling air is expelled
Optional
»Web / SNMP
»Modbus
»Relays
communication is achieved
through the use of a CAN bus
connection loop. This has
the effect of producing a
highly reliable system with
“no single points of failure”.
through vents on the top of the
unit. This new design also gives »Modem
the user significant savings in
»Remote panel
floor utilization and is an ideal
solution where space is at a
premium.
Intelligent design of the
system connections allow
for easy installation and
easy future upgrades, this
allows for upgrading in the
field without difficulty.
Options
»Parallel capacity / redundancy
Despite the modern, compact
design, all critical components,
are accessible from the front
of the unit; this improves
accessibility to allow regular
maintenance and reduced
Mean Time to Repair (MTTR).
»Sync control for dual
feed systems
»Isolation transformer
»External bypass
»External battery cabinets
»Battery switch box
»Battery thermal probe
In modular arrangement,
units can be added or
removed “hot” without
load disturbances or the
need to switch to bypass.
Fluxpower HPS also
incorporates a unique
Smart Parallel functions
facilitate the automatic
back-feed power protection
system. If the output of the
UPS is fed back into the mains,
the unit will immediately
isolate itself. This removes
the need for additional MCBs
or other similar safety devices.
»Transformers /
autotransformers for
voltage adaption
switching off of units where
the total power requirements
of the load is provided by
fewer than the total number
of UPS units attached.
This is commonly known as
“load based shutdown”
and maximizes the efficiency
of the complete system by
keeping the load on each
module at an optimum level.
»Top cable entry
Information and
communication
technology
User interface and
accessories
»Large data centers
»Server farms
»User-friendly interface
»Monitoring, managing
»Telecommunication
Two independent paralleled
systems can be synchronized
(Sync Control) in order to
feed downstream STS’ for
seamless transfers.
and shutdown software
installations
»Bypass and switchgear
»Broadcasting and
section
entertainment
»Power conversion section
»Removable blowers
»Front access
»Internet Service
Providers (ISP)
Critical electrical
engineering
Communication
»RS232 serial port
»USB port
»Remote EPO
»Industrial systems
»Financial and banking
»Security operations
»Transportation systems
»Medical / Healthcare
»External manual bypass status
»Battery Switch status
»Diesel Mode
Model (kVA)
400
400
500
500
600
600
800
800
Capacity rating (kVA)
Dimensions W x H x D (mm)
Weight (kg)
1990 x 1920 x 990 2440 x 2020 x 990 2440 x 2020 x 990 3640 x 1920 x 990
1820 2220 2400 3600
Hard wired (dual input)
FLUXPOWER
HPS
Input / output connection
Battery
SPECIFICATION
External, 300-312 cells
INPUT
Nominal voltage
Voltage range
220 / 380, 230 / 400, 240 / 415 VAC single / 3-phase
-20 %, +15 % at 400 V nominal
Frequency
50 / 60 Hz (45 – 65 Hz)
Power factor
0.99
Current distortion (THDi)
OUTPUT
<3.5 %
Nominal voltage
Frequency
220 / 380, 230 / 400, 240 / 415 V AC three phase
50 / 60 Hz
Voltage regulation
PF acceptable without de-rating
Overload capacity
1 % static; 5 % dynamic 100 % load change
Lagging to leading 0.9
101 – 125 % for 10 min (on-line), 126 – 150 % for 1 min (on-line),
1000 % for 1 cycle (bypass)
Efficiency; VFI, double-conversion
Efficiency; Wise ECO mode
OPTIONS
≤94.8 %
95 – 98 % (>98 %)
General
8 x parallel capacity/redundancy, sync control, isolation transformer, external
bypass, external battery cabinets, battery switch box, battery thermal probe,
transformers / autotransformers for voltage adaption, top cable entry
USER INTERFACE
Front panel
Graphical LCD display, mimic with LED’s and keyboard
Standard communication ports
RS232 serial, USB, Remote Emergency Power Off input, Battery Switch status
monitoring, External Manual Bypass status monitoring, Diesel Mode
Optional communication
Web / SNMP, ModBus, Relay, Modem cards; Remote panel;
Monitoring, Managing and shutdown software
ENVIRONMENTAL
Operating temperature
Storage temperature
Altitude
0 °C – +40 °C
-10 °C – +70 °C
<1000 m; 1 % power derating each 100 m above, max. 2000 m
<60
Audible noise at 1 meter dB(A)
STANDARDS AND CERTIFICATION
Marking and certification
Safety
CE, GOST, ECA ETL
IEC EN 62040-1
EMC
IEC EN 62040-2
Test and Performance
Quality, environment, health and safety
IEC EN 62040-3
ISO9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
AEG Power Solutions
Approach your local AEG Power Solutions
representative for further support.
Contact details can be found on:
|