ADC Stereo Amplifier Tower Mounted Amplifiers User Manual

ClearGain® Tower-Mounted Amplifiers  
Americas  
As mobile usage continues to increase, service providers are faced with the challenge of optimizing  
and expanding their wireless networks to provide new and existing services. ADCs ClearGain®  
Tower-Mounted Amplifiers (TMAs) minimize the cost of network expansion and improve quality of  
service, allowing service providers to increase profitability from new and existing services.  
The ClearGain TMAs improve signal quality by boosting the uplink signal of a mobile system to  
increase receiver performance and improve overall coverage.  
Features:  
• Provides amplification of the Band  
• Highly advanced LNA amplifies RX signal for improved receiver performance  
and increase in coverage  
• Dual duplex feature reduces the number of feeder cable runs by providing simultaneous  
operation of TX and RX with low TX loss  
• Full Band feature provides amplification of the entire band  
• Advanced filtering maintains the lowest possible noise figure for improved quality of service  
• Slim, stackable design conserves tower space and reduces tower-related costs  
• Seamless aluminum sleeve construction protects components from the elements  
• Modular system is fully compatible with all base stations  
• Power and alarming for up to six masthead units is provided from a single unit at the base station  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
DD800 Full Band Typical Specifications  
ELECTRICAL  
Nominal Impedance of RF Inputs and Outputs:  
Frequency Range:  
TX:  
50 Ohm  
869-894 MHz  
824-849 MHz  
RX:  
Passband (RX)  
Gain:  
12 dB  
Noise Figure:  
1.5 dB  
Dynamic Range  
Input at 1 dB Gain Compression:  
IIP3:  
0 dBm  
+13 dBm  
+10 dBm  
<30 dB  
2.0 dB  
80 dB  
Max Input Power:  
851 MHz Rejection:  
Bypass Insertion Loss:  
Isolation in Tx Path:  
Rejection 1850-1998 MHz:  
Insertion Loss of TX Path (TX to Antenna):  
Passband Return Loss  
TX Band:  
RX Band:  
Intermodulation:  
Maximum Input Power (RMS Power):  
Tx Rejection in Rx Band:  
80 dB  
0.4 dB  
>18 dB  
>18 dB  
-120 dBm  
500 W  
40 dB  
POWER  
Operational Voltage:  
Operational Current:  
7 to 15 Vdc  
140 10 mA  
PHYSICAL  
Dimensions (HxWxD):  
Weight:  
Color:  
332 mm x 250 mm x 84 mm  
6.3 kg (13.9 lbs.)  
Silver  
Housing:  
Aluminum  
CONNECTORS  
Antenna Connector:  
BTS Connector:  
7/16 DIN female  
7/16 DIN female  
ENVIRONMENTAL  
Operating Temperature:  
Lightning Protection:  
Vibration  
-40°C to +60°C  
IEC 61000-4-5  
Storage:  
Transport:  
Operation:  
ETS3019-1-1  
ETS3019-1-2  
ETS3019-1-3  
REGULATORY  
EMC:  
ETS300 342-2  
APPROVALS  
FCC:  
UL:  
Part 15, Class A  
1950  
QUALITY  
MTBF:  
900,000 hours  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
3
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
DD800 B-Band Typical Specifications  
ELECTRICAL  
Nominal Impedance of RF Inputs and Outputs:  
Frequency Range:  
50 Ohm  
TX:  
RX:  
880-894 MHz  
835-849 MHz  
Passband (RX)  
Gain:  
12 dB  
Noise Figure:  
1.7 dB  
Dynamic Range  
Input at 1 dB Gain Compression:  
IIP3:  
0 dBm  
+13 dBm  
+10 dBm  
>35 dB  
2.0 dB  
80 dB  
Max Input Power:  
Antenna Isolation 851-869 MHz:  
Bypass Insertion Loss:  
Isolation in Tx Path:  
Rejection 1850-1998 MHz:  
Insertion Loss of TX Path (TX to Antenna):  
Passband Return Loss  
TX Band:  
RX Band:  
Intermodulation:  
Maximum Input Power (RMS Power):  
Tx Rejection in Rx Band:  
80 dB  
0.4 dB  
>18 dB  
>18 dB  
-120 dBm  
500 W  
40 dB  
POWER  
Operational Voltage:  
Operational Current:  
Alarm Current Level:  
7 to 20 Vdc  
140 10 mA  
350 10 mA  
PHYSICAL  
Dimensions (HxWxD):  
332 mm x 250 mm x 84 mm  
(13 in x 9.8 in x 3.3 in)  
6.3 kg (13.9 lb)  
Silver  
Weight:  
Color:  
Housing:  
Aluminum  
CONNECTORS  
Antenna Connector:  
BTS Connector:  
7/16 DIN female  
7/16 DIN female  
ENVIRONMENTAL  
Operating Temperature:  
Lightning Protection:  
Vibration  
-40° to +60° C  
IEC 61000-4-5  
Storage:  
Transport:  
Operation:  
ETS3019-1-1  
ETS3019-1-2  
ETS3019-1-4  
REGULATORY  
EMC:  
ETS300 342-2  
APPROVALS  
FCC:  
UL:  
Part 15, Class A  
1950  
QUALITY  
MTBF:  
900,000 hours  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
DD1900 Full Band Typical Specifications  
ELECTRICAL  
Nominal Impedance of RF Inputs and Outputs:  
Frequency Range  
50 Ohm  
TX:  
RX:  
1930-1990 MHz  
1850-1910 MHz  
Passband (RX)  
Gain:  
12 dB  
Noise Figure:  
1.6 dB  
Dynamic Range  
Input at 1 dB Gain Compression:  
IIP3:  
+3 dBm  
+13 dBm  
+10 dBm  
<15 dB  
<30 dB  
2.0 dB  
80 dB  
Max Input Power:  
1915 MHz Rejection:  
1916 MHz Rejection:  
Bypass Inserion Loss:  
Isolation in Tx Path:  
Rejection 824-894 MHz:  
Insertion Loss of TX Path (TX to Antenna):  
Passband Return Loss  
TX Band:  
RX Band:  
Intermodulation:  
Maximum Input Power (RMS Power):  
Tx Filter Rejection in Rx Band:  
80 dB  
.4 dB  
>18 dB  
>18 dB  
-120 dBm  
250 W  
40 dB  
POWER  
Operational Voltage:  
Operational Current:  
Alarm Current Level:  
7 to 15 Vdc  
140 10 mA  
350 20 mA  
PHYSICAL  
Dimensions (HxWxD):  
Weight:  
Color:  
297 mm x 287 mm x 70 mm  
5.5 kg (12.1 lbs.)  
Silver  
Housing:  
Aluminum  
CONNECTORS  
Antenna Connector:  
BTS Connector:  
7/16 DIN female  
7/16 DIN female  
ENVIRONMENTAL  
Operating Temperature:  
Lightning Protection:  
Vibration  
-40ºC to +60ºC  
IEC61000-4-5  
Storage:  
Transport:  
Operation:  
ETS3019-1-1  
ETS3019-1-2  
ETS3019-1-3  
REGULATORY  
EMC:  
ETS300 342-2  
APPROVALS  
FCC:  
UL:  
Part 15, Class A  
1950  
QUALITY  
MTBF:  
900,000 hours  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
5
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
DD1900 Full Band with 800 Bypass Typical Specifications  
ELECTRICAL  
Nominal Impedance of RF Inputs and Outputs:  
Frequency Range  
50 Ohm  
TX:  
RX:  
1930-1990 MHz  
1850-1910 MHz  
Passband (RX)  
Gain:  
12 dB  
Noise Figure:  
1.6 dB  
Dynamic Range  
Input at 1 dB Gain Compression:  
IIP3:  
+3 dBm  
+15 dBm  
4 dB  
<15 dB  
<30 dB  
2.0 dB  
80 dB  
Insertion Loss TX Path (TX to ANT): .  
1915 MHz Rejection:  
1916 MHz Rejection:  
Bypass Insertion Loss:  
Isolation in Tx Path:  
Rejection 824-894 MHz:  
Max Input Power:  
Passband Return Loss  
TX Band:  
RX Band:  
Intermodulation:  
Maximum Input Power (RMS Power):  
Tx Filter Rejection in Rx Band:  
80 dB  
+10 dBm  
>18 dB  
>18 dB  
-120 dBm  
250 W  
40 dB  
POWER  
Operational Voltage:  
Operational Current:  
Alarm Current Level:  
7 to 20 Vdc  
140 10 mA  
350 20 mA  
PHYSICAL  
Dimensions (HxWxD):  
Weight:  
Color:  
297 mm x 287 mm x 70 mm  
5.5 kg (12.1 lbs.)  
Silver  
Housing:  
Aluminum  
CONNECTORS  
Antenna Connector:  
BTS Connector:  
7/16 DIN female  
7/16 DIN female  
ENVIRONMENTAL  
Operating Temperature:  
Lightning Protection:  
Vibration  
-40°C to +60°C  
IEC 61000-4-5  
Storage:  
Transport:  
Operation:  
ETS3019-1-1  
ETS3019-1-2  
ETS3019-1-3  
REGULATORY  
EMC:  
ETS300 342-2  
APPROVALS  
FCC:  
UL:  
Part 15, Class A  
1950  
QUALITY  
MTBF:  
900,000 hours  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
6
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
Dual Band 800/1900 MHz Full Band Typical Specifications  
ELECTRICAL  
Nominal Impedance of RF Inputs and Outputs:  
Frequency Range  
50 Ohm  
TX:  
800:  
1900:  
800:  
869-894 MHz  
1930-1990 MHz  
824-849 MHz  
1850-1910 MHz  
25/60 MHz  
RX:  
1900:  
Filter Bandwidth:  
Passband (RX)  
Gain:  
12 dB  
Noise Figure:  
800:  
1900:  
1.5 dB  
1.6 dB  
Dynamic Range  
Input at 1 dB Gain Compression:  
IIP3:  
+0 dBm  
+13 dBm  
+10 dBm  
<30 dB  
<15 dB  
<30 dB  
2.0 dB  
Max. Input Power:  
851 MHz Rejection:  
1915 MHz Rejection:  
1916 MHz Rejection:  
Bypass Insertion Loss:  
Isolation in TX Path:  
Insertion Loss of TX Path (TX to Antenna):  
Passband Return Loss:  
TX Band:  
80 dB  
4 dB  
>18 dB  
RX Band:  
>18 dB  
Intemodulation:  
Max. Input Power (RMS Power):  
800:  
-120 dBm  
500 W  
250 W  
40 dB  
1900:  
Tx Filter Rejection in RX Path:  
POWER  
Operational Voltage:  
Operational Current:  
Alarm Current Level:  
PHYSICAL  
7 to 20 Vdc  
280 10 mA  
350-520 mA  
Dimensions (HxWxD):  
Weight:  
Color:  
357 mm x 287 mm x 149 mm  
10.5 kg (22.5 lbs.)  
Silver  
Housing:  
Aluminum  
CONNECTORS  
Antenna Connector:  
BTS Connector:  
ENVIRONMENTAL  
Operating Temperature:  
Lightning Protection:  
Vibration:  
7/16 DIN female  
7/16 DIN female  
-40° to +60 °C  
IEC 61000-4-5  
Storage:  
Transport:  
Operation:  
ETS3019-1-1  
ETS3019-1-2  
ETS3019-1-3  
REGULATORY  
EMC:  
ETS300 342-2  
APPROVALS  
FCC:  
UL:  
Part 15, Class A  
1950  
QUALITY  
MTBF:  
900,000 hours  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
STRB-NF-NM-G-KIT  
STRB-NM-NF-G-KIT  
STRB-DM-DF-G-KIT  
STRB-DF-DM-G-KIT  
Bias-T Units  
ADCs newly enhanced Bias-T Units can be used indoors and outdoors in conjunction with the ClearGain  
power distribution unit (PDU). These versatile units, also known as a DC current injector, insert DC  
power into the coaxial cable and extract alarm and monitoring signals from the coaxial cable. These  
units can also be used with a SMART PDU.  
Bias-T Unit Typical Specifications  
PRODUCT CONFIGURATION  
Main path connectors:  
DC injection/Sample port connector:  
Mounting and grounding:  
Refer to ordering information for configurations  
TNC jack (female)  
/M8 / brk (MH - bulkhead mounting/ M -  
screw / brk - bracket)  
TECHNICAL DATA  
Impedance:  
50 ohms  
Frequency range:  
Return loss:  
800 to 2200 MHz  
> 19 dB  
Insertion loss:  
< 0.2 dB  
RF CW power:  
500 W  
PIM 3rd order:  
-108 dBm  
Surge current handling capability:  
Operating temperature:  
Waterproof degree:  
DC injection / DC bypass current:  
DC supply / DC bypass voltage:  
MTBF:  
3kA single  
-40°C to + 65°C  
IP 65  
< 2 A  
< 48 V  
600,000 hours  
125 mm x 110 mm x 45 mm  
(4.9 in x 4.3 in x 1.8 in)  
0.8 kg (1.8 lbs.)  
Size:  
Weight:  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
8
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
Singlemode and Dual Mode 800/1900 MHz Power Distribution Unit  
Time and space are important considerations when selecting and installing wireless components at base  
transceiver station sites. The simple, compact design of ADCs ClearGain Power Distribution Unit (PDU) is  
intended to help service providers save both. From a compact unit that is easily mounted on a wall or a  
rack, ClearGain PDUs provide power and alarming for ADCs tower-mounted amplifiers.  
Features:  
• Provides power and alarm functions for on-site monitoring of masthead units (MHUs)  
• Monitors condition of feeder cable  
• Wall- or rack-mountable to fit available space  
• LED indicators for alarm functions  
• Simple, compact design allows for easy installation and connections  
The ClearGain PDU is an integrated unit that provides power and alarm functions for the ClearGain  
TMA system. The ClearGain Singlemode PDU provides power for up to six single frequency TMAs. For  
dual band systems, the ClearGain Dual Mode PDU provides power for up to six dual band TMAs or  
twelve multi-frequency systems that amplify a single frequency.  
The PDU monitors the current of the MHU. If an MHU fails, the ClearGain PDU gives an alarm  
indication. The ClearGain PDU also monitors the condition of the feeder cable. Alarm indicators identify  
failure in the feeder cable or MHUs and in which MHU the failure occurred, providing fast and easy on-  
site diagnostics. The flexible design of ClearGain PDUs allows them to be rack-mounted or mounted  
indoors on the wall or on the side of a BTS cabinet.  
An external Bias-T unit is used in conjunction with the PDU and is designed to connect directly into the  
BTS coaxial connector. Bias-T units are available with various connector types, with gas tube arrestors for  
lightning protection on the ANT and MHU ports. Quarter wave stub lightning protection is integrated on  
the BTS port of the Bias-T units.  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
9
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
Singlemode and Dual Mode 800/1900 MHz PDU Typical Specifications  
ELECTRICAL  
Input Voltage:  
20-56 Vdc positive/negative ground  
Output Voltage:  
Maximum Current Drawn:  
18 Vdc each  
3.8A  
PHYSICAL  
Dimensions (HxWxD):  
Weight:  
Color:  
43 x 196 x 103 mm (1.69" x 7.72" x 4.06")  
<460 g  
Silver  
CONNECTORS  
Output for MHUs:  
Power Connector:  
General Alarm Connector:  
Indicators  
SMB, male (qty 6)  
4-pin male  
3-pin male  
Singlemode PDU:  
Red General Alarm LED  
Dual Mode PDU:  
Red General Alarm LEDs  
Alarm output:  
Green OK/NOK LEDs  
Green/Yellow OK/NOK LEDs  
Alarm output is isolated 3-pin relay connection  
Normally open and normally closed connection  
available  
ENVIRONMENT  
Storage:  
ETS3019-1-1  
Transport:  
ETS3019-1-2  
Operation:  
ETS3019-1-3  
Housing:  
IP40  
Temperature Range (Indoor Use):  
Lightning Protection:  
APPROVALS  
-20ºC to +65ºC (-4ºF to +149ºF)  
IEC 1000-4-5 EMC  
UL  
QUALITY  
MTBF 250,000 hours. Manufactured under  
ISO 9001 quality system  
ACCESSORIES  
Basic Accessories:  
Power supply cable (10 m), alarm cable (10 m),  
grounding cable (2 m) and wall mounting screws  
Mounting hardware for 19” rack mount  
Optional Accessories:  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
10  
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
O rd e r i n g I n f o r m a t i o n  
Description  
Catalog Number  
ClearGain Masthead Units  
DD800 Full Band  
CG-800DD-FULL-DIN  
CG0800DDB14DTTX  
CG-1900DD-FULL-DIN  
CG1900DDBFBDTBP  
CG-1900/800-DB-FB-DIN  
DD800 B-Band  
DD1900 Full Band  
DD1900 Full Band w/800 Bypass  
Full Band 800/1900 MHz  
Bias-T Kits*  
7/16 DIN male to BTS, 7/16 DIN female to ANT  
7/16 DIN female to BTS, 7/16 DIN male to ANT  
N male to BTS, N female to ANT  
N female to BTS, N male to ANT  
Power Distribution Units  
STRB-DM-DF-G-KIT  
STRB-DF-DM-G-KIT  
STRB-NM-NF-G-KIT  
STRB-NF-NM-G-KIT  
Single Mode PDU; includes power cable and grounding cable  
Dual Mode PDU; includes power cable and grounding cable  
CG-PDU-SMPWR  
CG-PDU-DMPWR  
*Bias-T, DC Cable 4.25 meters (SMB to TNC), Grounding Cable 1.5 meters (one end terminated)  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
11  
 
ClearGain® Tower-Mounted Amplifiers  
Americas  
Creating a Bill of Materials  
A typical site includes three components in various quantities.  
You have six TMA options:  
1. CG-800DD-FULL-DIN  
2. CG-800DDB14DT00  
3. CG-1900DD-FULL-DIN  
4. CG-1900W800-FULL-DIN  
5. CG1900DDBFBDTBP  
DD800 Full Band TMA, DIN Connectors  
DD800 B-Band TMA, DIN Connectors  
DD1900 Full Band TMA, DIN Connectors  
DD1900 with 800 Bypass Full Band TMA, DIN Connectors  
DD1900 with 800 Bypass Full Band TMA with  
DC Block, DIN Connectors  
6. CG-1900/800-DB-FB-DIN  
Dual Band-Full Band TMA, DIN Connectors  
The TMAs include:  
• Mounting hardware  
• Grounding cable/strap (length 1.5 meters)  
Ordering information: Order two per sector  
You have four Bias-T options (based on connector type and orientation):  
1. STRB-DF-DM-G-KIT  
2. STRB-DM-DF-G-KIT  
3. STRB-NF-NM-G-KIT  
4. STRB-NM-NF-G-KIT  
DIN Female to BTS Port, DIN Male to ANT Port  
DIN Male to BTS Port, DIN Female to ANT Port  
N Female to BTS Port N Male to ANT Port  
N Male to BTS Port, N Female to ANT Port  
The Bias-Ts include: • Grounding cable/strap (length 1.5 meters)  
• Bias-T cable; go from Bias-T to the PDU (length 14 feet)  
Ordering information: Order two per sector  
You have two PDU options:  
1. CG-PDU-SMPWR  
2. CG-PDU-DMPWR  
Single Power PDU  
Dual Power PDU*  
*Typically used in conjunction with the Dual Power TMA  
The PDUs include:  
• Power cable (length 10 meters)  
• Alarm cable (length 10 meters)  
• Grounding cable/strap (length 1.5 meters)  
Ordering information: Order one per site  
Optional Accessories:  
Longer Bias-T Cable CG-PDU-30CABLE (30 foot Bias-T cable)  
PDU Rack Mounting Brackets AUX-000076 (19" rack mounting bracket)  
AUX-000076 and EB-17P (23" mounting bracket)  
AUX-000084 (Siemens cabinet mounting bracket)  
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080  
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.  
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101  
Specifications published here are current as of the date of publication of this document. Because we are continuously  
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may  
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.  
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features  
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer  
105187AE 8/07 Original © 2007 ADC Telecommunications, Inc. All Rights Reserved  
 

Acer Computer Monitor P205H User Manual
ADIC Tool Storage Version 27 User Manual
ADTRAN Network Card SLC 5 U BR1TE III User Manual
AEG Freezer AGS58200F0 User Manual
Alienware Switch A9090 User Manual
Alliance Laundry Systems Clothes Dryer Dryer Tumblers User Manual
Allied Telesis Power Supply AT PWR1200 User Manual
Altec Lansing Speaker CF108 4T User Manual
Aluratek eBook Reader AEBK01FS User Manual
Barco Home Theater System PGWU 618 User Manual