HB6000, HB6000/220, and
HB6024
Heater/Blower Kits
Installation/Operation
Manual C496M (12/90)
2.0 SCOPE
1.0 WARNINGS
The information within this manual covers the installa-
tion of the HB6000, HB6000/220, and HB6024 Heater/
Blower Kits.
Priortoinstallationanduseofthisproduct,thefollowing
WARNINGS should be observed.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
3.0 DESCRIPTION
The HB6000 (120 VAC), HB6000/220 (230 VAC), and
the HB6024 (24 VAC) are field installed heater/blower
kits for the HS1000 and HS6000 series high security
enclosures. These heater/blower kits will help stabilize
the internal enclosure temperatures when the enclosures
are subjected to more extreme conditions.
2. Installation should be in accordance with all
applicablelocalandnationalelectriccodes,utilizing
approve materials only.
3. OnlyusereplacementpartsrecommendedbyPelco.
The heaters provide 80 watts of heat thermostatically
controlled to turn ON at 40°F (4.44°C) and OFF at 60°F
(15.56°C).
Please thoroughly familiarize yourself with the informa-
tion in this manual prior to installation and operation.
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
International customers call (1-559) 292-1981 or FAX (1-559) 348-1120
4.2 BLOWER/PCB ASSEMBLY
3.4 POWER REQUIREMENTS
1. Open the cover or access door(s).
The blower and heater require a 24 VAC/120 VAC/230
VAC, 50/60 Hz single phase power source. They use
the following wattage when in operation.
2. On the HS1000, the blower/PCB bracket is de-
signed to attach to any two (2) adjacent studs re-
taining the bottom plate. On the HS6000, the
blower/PCB bracket is designed to attach to the
two (2) studs at the bottom of the window.
Blower:
Heater:
4.5 watts
80 watts
4.0 INSTALLATION
3. On the HS1000, remove any two (2) adjacent nuts
and washers retaining the bottom plate to the
mounting frame. On the HS6000, remove the nuts
and washers retaining the bottom of the window.
To install the HB6000, HB6000/220, and HB6024 per-
form the following steps. Refer to Figure 1.
4.1 HEATER ASSEMBLY
4. Place the blower/PCB bracket over the studs and
replace and tighten the hardware
1. Open the cover or access door.
2. The heater brackets are designed to attach to two
(2) adjacent studs retaining the window.
3. Remove any two (2) adjacent nuts and washers
(preferably at the bottom of the window) on both
sides of the window.
4. Place the heater brackets on the studs, heaters
angled away from the window, and replace and
tighten the hardware.
Figure 1. HB6000, HB6000/220, and HB6024 Assembly
Pelco Manual C496M (12/90)
3
4.3 HEATER/BLOWER WIRING
4.4 ELECTRICAL CONNECTION
The blower is factory wired to the PCB assembly.
After the cable has been routed, all wire connections
should be made (i.e., video, lens, camera power, heat-
ers). A 6-position terminal block has been provided to
assist in this.
Connect the heaters to the PCB assembly as shown in
the respective wiring diagrams (refer to Figure 2, Fig-
ure 3, or Figure 4).
CAUTION: When using a single power
source for both the camera and accessories, the
camera power consumption must be taken into
consideration when determining the wire gauge.
Also, make certain that all electrical connec-
tions are done properly and meet electrical
codes.
SupplyAC line voltage (230 VAC, 120 VAC, or 24 VAC)
as shown.
Figure 2. HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC)
4
Pelco Manual C496M (12/90)
|